Mechanical Flexibility Reduces the Foreign Body Response to Long-Term Implanted Microelectrodes in Rabbit Cortex
Open Access
- 27 October 2016
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (10) , e0165606
Abstract
Micromotion between the brain and implanted electrodes is a major contributor to the failure of invasive microelectrodes. Movements of the electrode tip cause recording instabilities while spike amplitudes decline over the weeks/months post-implantation due to glial cell activation caused by sustained mechanical trauma. We compared the glial response over a 26–96 week period following implantation in the rabbit cortex of microwires and a novel flexible electrode. Horizontal sections were used to obtain a depth profile of the radial distribution of microglia, astrocytes and neurofilament. We found that the flexible electrode was associated with decreased gliosis compared to the microwires over these long indwelling periods. This was in part due to a decrease in overall microgliosis and enhanced neuronal density around the flexible probe, especially at longer periods of implantation.Keywords
All Related Versions
Funding Information
- Engineering and Physical Sciences Research Council
- Medical Research Council
- Wellcome Trust
This publication has 29 references indexed in Scilit:
- Novel flexible Parylene neural probe with 3D sheath structure for enhancing tissue integrationLab on a Chip, 2012
- Ultrasmall implantable composite microelectrodes with bioactive surfaces for chronic neural interfacesNature Materials, 2012
- Novel multi-sided, microelectrode arrays for implantable neural applicationsBiomedical Microdevices, 2011
- Reduction of neurovascular damage resulting from microelectrode insertion into the cerebral cortex usingin vivotwo-photon mappingJournal of Neural Engineering, 2010
- Quantitative analysis of the tissue response to chronically implanted microwire electrodes in rat cortexBiomaterials, 2010
- Single-Unit Stability Using Chronically Implanted Multielectrode ArraysJournal of Neurophysiology, 2009
- Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertionJournal of Neural Engineering, 2006
- A finite-element model of the mechanical effects of implantable microelectrodes in the cerebral cortexJournal of Neural Engineering, 2005
- Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arraysExperimental Neurology, 2005
- Body surface maps in the somatosensory cortex of rabbitJournal of Comparative Neurology, 1986