This paper presents a procedure for designing precast tunnel segments for mechanically excavated tunnel linings in fibre‐ reinforced concrete, without any traditional steel reinforcement. Both ultimate and serviceability limit states are considered as well as structural checks at different construction stages of the segment, including demoulding, positioning on floor, storage, transportation, handling and the final stage concerning the loads due to the ground pressure.The structural checks are performed by means of bending moment‐axial force interaction envelopes for both the considered limit states, once the constitutive relationship of the material is defined for each stage. Traditional interaction envelopes are drawn for the ultimate limit state check, whereas for the serviceability limit state check, envelopes obtained by limiting the maximum crack opening and maximum concrete compressive stress are proposed. The shear action is also accounted for by reducing the bending moment‐axial force envelope. The possibility of having the assistance of a test procedure for particular loading situations is also proposed. Finally, a case study related to a precast steel fibre‐reinforced concrete segment is analysed in order to clarify the procedure and show, practically, how to define the actions and evaluate the interaction envelopes.Keywords
This publication has 14 references indexed in Scilit:
- Experimental and analytical study of concrete blocks subjected to concentrated loads with an application to TBM-constructed tunnelsTunnelling and Underground Space Technology, 2015
- On shear verification according to fib Model Code 2010 in FRC elements without traditional reinforcementStructural Concrete, 2015
- Design of FRC tunnel segments considering the ductility requirements of the Model Code 2010Tunnelling and Underground Space Technology, 2015
- Concrete crack reduction in tunnel linings by steel fibre-reinforced concretesConstruction and Building Materials, 2013
- Design according to MC2010 of a fibre‐reinforced concrete tunnel in Monte Lirio, PanamaStructural Concrete, 2012
- Experiences in Barcelona with the use of fibres in segmental liningsTunnelling and Underground Space Technology, 2012
- Structural behaviour of precast tunnel segments in fiber reinforced concreteTunnelling and Underground Space Technology, 2011
- Tensile behaviour of FRC under high strain-rateMaterials and Structures, 2009
- Lining design for the district heating tunnel in Copenhagen with steel fibre reinforced concrete segmentsTunnelling and Underground Space Technology, 2008
- Final recommendation of RILEM TC 162-TDF: Test and design methods for steel fibre reinforced concrete sigma-epsilon-design methodMaterials and Structures, 2003