Abstract
Objective: To determine whether gastroenteritis viruses and other enteric viruses could be detected in faecal specimens collected with Bio‐wipes.Methods: Faecal specimens, self‐collected with Bio‐wipes, from 190 individuals (94 diarrhoeal, 93 non‐diarrhoeal, 3 unknown) were screened for eight human enteric viruses (enterovirus, hepatitis A virus, adenovirus, astrovirus, norovirus GI and GII, sapovirus and rotavirus) by real‐time (reverse transcription)‐polymerase chain reaction. Rotaviruses and noroviruses from positive specimens were genotyped.Results: At least one enteric virus could be detected in 82.6% (157/190) of faecal specimens. Mixed infections of up to four different viruses could be detected in both diarrhoeal and non‐diarrhoeal specimens. Enteroviruses were detected most frequently (63.7%), followed by adenoviruses (48.4%) and noroviruses (32.2%). Genotyping was successful for 78.6% of rotaviruses and 44.8% of noroviruses.Conclusions: Bio‐wipes provide a user friendly, easier method for stool collection that facilitates enteric virus detection and genetic characterisation.
Funding Information
  • Water Research Commission, South Africa (K5/1653)

This publication has 30 references indexed in Scilit: