Response characteristics of an aquatic biomonitor used for rapid toxicity detection
- 1 September 2004
- journal article
- research article
- Published by Wiley in Journal of Applied Toxicology
- Vol. 24 (5) , 387-394
Abstract
The response characteristics of an aquatic biomonitor that detects toxicity by monitoring changes in bluegill (Lepomis macrochirus Rafinesque) ventilatory and movement patterns were evaluated in single chemical laboratory studies at concentrations near the 96‐h LC50 concentration and at the EILATox‐Oregon Workshop in sequential tests of multiple unknown samples. Baseline data collected prior to exposure allows each fish to serve as its own control. When at least 70% of exposed fish exhibit ventilatory or movement parameters significantly different from baseline observations, a group alarm is declared. In the laboratory studies, the aquatic biomonitor responded to the majority of chemicals at the 96‐h lc50 within an hour or less, although substantially higher response times were found for malathion and pentachlorophenol. Workshop tests of single chemical concentrations presented as blind samples were consistent with the laboratory test results. There were no alarms under control conditions in any test. Although data are limited, the aquatic biomonitor appears to respond more rapidly to chemicals causing membrane irritation, narcosis or polar narcosis than to acetylcholinesterase inhibitors or oxidative phosphorylation uncouplers. All four monitored parameters (ventilatory rate, cough rate, ventilatory depth and movement) contributed to identification of first alarms at acutely toxic levels. Understanding these response patterns can be useful in data interpretation for biomonitor applications such as surface water monitoring for watershed protection, wastewater treatment plant effluent monitoring or source water monitoring for drinking water protection. Copyright © 2004 John Wiley & Sons, Ltd.Keywords
This publication has 20 references indexed in Scilit:
- Long-Term Operation of an Automated Fish Biomonitoring System for Continuous Effluent Acute Toxicity SurveillanceBulletin of Environmental Contamination and Toxicology, 2001
- Predicting modes of toxic action from chemical structure: Acute toxicity in the fathead minnow (Pimephales promelas)Environmental Toxicology and Chemistry, 1997
- Performance characteristics of a fish monitor for detection of toxic substances—I. Laboratory trialsWater Research, 1994
- Rapid detection of sublethal toxicity using fish ventilatory behaviorEnvironmental Toxicology and Chemistry, 1990
- The influence of pH, dissolved oxygen, suspended solids or dissolved solids upon ventilatory and cough frequencies in the bluegill Lepomis macrochirus and brook trout Salvelinus fontinalisEnvironmental Pollution Series A, Ecological and Biological, 1984
- Toxicity of selected priority pollutants to various aquatic organismsEcotoxicology and Environmental Safety, 1983
- Biological monitoring part I—Early warning systemsWater Research, 1980
- Detection limits of a biological monitoring system based on fish respirationBulletin of Environmental Contamination and Toxicology, 1979
- Fish bioassay monitoring of waste effluentsEnvironmental Management, 1979
- Trimmed Spearman-Karber method for estimating median lethal concentrations in toxicity bioassaysEnvironmental Science & Technology, 1977