A wearable monitoring system for running gait analysis by diffusion transformer
Authors:
Open Access
- 23 January 2026
- journal article
- physics
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (1) , e0341066
Abstract
Conventional wearable monitoring devices often suffer from insufficient data accuracy and low posture recognition rates, making them inadequate for the demands of professional sports health monitoring. To address these issues, this study proposes a wearable monitoring system for running gait analysis based on the Diffusion Transformer (DiT). The system aims to achieve high-precision running posture recognition and real-time motion monitoring through multi-sensor data fusion and advanced deep learning architecture. First, a wearable system was developed using a nine-axis Micro-Electro-Mechanical System (MEMS) inertial sensor and an UltraWide Band (UWB) positioning module. Data quality was enhanced through sensor calibration, noise compensation, and an adaptive filtering algorithm. Then, a DiT-LSTM running posture recognition model was constructed by integrating the DiT with a Long Short-Term Memory (LSTM) network to perform posture recognition within the wearable system. Experimental results show that on the Human3.6M dataset, the DiT-LSTM model achieved an accuracy of 97.54%, a precision of 97.61%, a recall of 97.73%, an F1-score of 97.58%, and an Area Under the Curve (AUC) of 98.61%. On the HumanEva dataset, the model attained an accuracy of 96.39%, a precision of 96.47%, a recall of 96.8%, an F1-score of 96.92%, and an AUC of 97.9%, all outperforming other algorithms. The complexity assessment showed that DiT-LSTM reached 14.7 GFLOPs on the Human3.6M dataset, with a per-epoch training time of 62.3 seconds, while its per-sample inference latency was only 9.4 ms, meeting real-time monitoring requirements. In the UWB-based position drift correction experiment, Sample 1 achieved mean errors of 0.637 m, 0.581 m, and 0.349 m on the X/Y/Z axes, with corresponding RMSE values of 0.041 m, 0.023 m, and 0.025 m, demonstrating high positioning accuracy and stability. By combining multimodal sensors with the DiT-LSTM model, the study offers reliable technical support for running gait analysis, injury prevention, and personalized training guidance.Keywords
This publication has 29 references indexed in Scilit:
- Exploiting multi-transformer encoder with multiple-hypothesis aggregation via diffusion model for 3D human pose estimationMultimedia Tools and Applications, 2024
- A novel method for accurate division of the gait cycle into seven phases using shank angular velocityGait & Posture, 2024
- Pose pattern mining using transformer for motion classificationApplied Intelligence, 2024
- Electromechanical performance of flexible sensor based on 3D printed biomimetic all-PDMS-coated multistage structure: Toward kinesiology monitoring and human-machine interactionSensors and Actuators A: Physical, 2024
- A systematic review of user - conducted calibration methods for MEMS-based IMUsMeasurement, 2023
- RETRACTED ARTICLE: An image classification algorithm for football players’ activities using deep neural networkSoft Computing, 2023
- Real-time yoga pose classification with 3-D pose estimation model with LSTMMultimedia Tools and Applications, 2023
- A visual intelligent system for students’ behavior classification using body pose and facial features in a smart classroomMultimedia Tools and Applications, 2023
- Transformer for Skeleton-based action recognition: A review of recent advancesNeurocomputing, 2023
- Optimal design of active-passive shoulder exoskeletons: a computational modeling of human-robot interactionMultibody System Dynamics, 2022