EXPERIMENTAL STUDIES AND PARAMETER OPTIMIZATION OF SEPARATION OF COPPER USING HOLLOW FIBER–SUPPORTED LIQUID MEMBRANE
- 4 March 2013
- journal article
- research article
- Published by Taylor & Francis in Chemical Engineering Communications
- Vol. 200 (9) , 1237-1250
Abstract
The separation of copper from a leach liquor bearing 204.59 mol/m3 Cu, 40.83 mol/m3 Zn, 33.94 mol/m3 Co, 255.58 mol/m3 Ni, and 75.72 mol/m3 (NH4)2SO4 has been carried out with a hollow fiber membrane using LIX 84-I as the mobile carrier. Central composite inscribed (CCI) design was used to design the experiments. The factors considered for the CCI design were pH, LIX 84-I concentration in the membrane phase, flow rate, and acid concentration in the strip solution. A reduced quadratic model was found to fit the experimental data. Detailed analysis of the effect of different factors as well as their interaction on the extraction of copper has been done. The optimized condition for maximum copper flux was found to be pH 4.5, 39.88% LIX 84-I, 360 mL/min flow rate, and 7% H2SO4 in strip solution. The highest copper flux of 7.46 × 10−5 mol/m2 · s was obtained experimentally at the above conditions, which is in good agreement with the predicted value of 7.57 × 10−5 mol/m2 · s.Keywords
This publication has 15 references indexed in Scilit:
- Extraction of Copper from Aqueous Solutions by Liquid Membrane ProcessesSolvent Extraction and Ion Exchange, 2010
- Recovery of copper from ammoniacal medium using liquid membranes with LIX 54Separation and Purification Technology, 2008
- Separation of copper from chalcopyrite leach liquor containing copper, iron, zinc and magnesium by supported liquid membraneSeparation and Purification Technology, 2008
- Modeling extraction separation of Nd(III) and La(III) from nitrate media in hollow‐fiber modulesAIChE Journal, 2007
- India’s first medium scale demonstration plant for treating poly-metallic nodulesMinerals Engineering, 2003
- Non-dispersive solvent extraction of Cu(II) by LIX 973N from ammoniacal/ammonium carbonate aqueous solutionsHydrometallurgy, 2002
- Hollow fiber supported liquid membrane: a novel technique for separation and recovery of plutonium from aqueous acidic wastesJournal of Membrane Science, 2001
- A hollow fiber supported liquid membrane based on Aliquat 336 as a carrier for rhodium(III) transport and preconcentrationJournal of Membrane Science, 2000
- Hollow Fiber Supported Liquid Membrane for the Separation/Concentration of Gold(I) from Aqueous Cyanide Media: Modeling and Mass Transfer EvaluationIndustrial & Engineering Chemistry Research, 1999
- Selective separation of copper with Lix 864 in a hollow fiber moduleTalanta, 1998