VISUAL OUTCOMES WITH 23-GAUGE TRANSCONJUNCTIVAL SUTURELESS VITRECTOMY
Authors:
- 1 February 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Retina
- Vol. 28 (2) , 258-262
Abstract
Purpose: To evaluate the outcomes of patients treated with 23-gauge transconjunctival sutureless vitrectomy for various posterior segment conditions. Methods: A retrospective chart review of 81 consecutive 23-gauge vitrectomy cases done by a single vitreoretinal surgeon for various posterior segment conditions was done. All surgery was performed using the two-step 23-gauge system developed by Dutch Ophthalmic Research Center. All patients had at least 3-month follow-up. Main outcome measures included visual acuity, intraocular pressure, and operative complications. Results: Mean follow-up was 6.5 months (range 3–9 months). Mean overall preoperative visual acuity was 20/150 and final acuity was 20/70 (P < 0.0001). Mean intraocular pressure on postoperative day 1 was 14 mmHg (range 6–28 mmHg). There was a single case of intraoperative retinal tear that required treatment with cryotherapy. Twenty eyes of 48 phakic eyes (42%) had worsening of cataracts in the postoperative period. There were no postoperative complications of endophthalmitis or retinal detachment. Conclusions: Twenty-three-gauge transconjunctival sutureless vitrectomy is an effective surgical technique in the management of vitreoretinal diseases. Complications were rare and compared favorably with published literature on 20-gauge and 25-gauge surgery.Keywords
This publication has 10 references indexed in Scilit:
- 25-Gauge Scleral Tunnel Transconjunctival VitrectomyAmerican Journal of Ophthalmology, 2006
- 25-Gauge Transconjunctival Sutureless Pars Plana VitrectomyEuropean Journal of Ophthalmology, 2006
- Longer-term Outcomes of Transconjunctival Sutureless 25-gauge VitrectomyAmerican Journal of Ophthalmology, 2005
- Outcomes of 140 Consecutive Cases of 25-Gauge Transconjunctival Surgery for Posterior Segment DiseaseOphthalmology, 2005
- TRANSCONJUNCTIVAL SUTURELESS 23-GAUGE VITRECTOMYRetina, 2005
- Sutureless vitrectomy surgeryOphthalmology, 2003
- Sutureless vitrectomy surgeryOphthalmology, 2003
- OFFICE-BASED SUTURELESS TRANSCONJUNCTIVAL PARS PLANA VITRECTOMYRetina, 2002
- Initial experience using the transconjunctival sutureless vitrectomy system for vitreoretinal surgery1 1The new Transconjunctival Sutureless Vitrectomy System is disclosed to Bausch & Lomb Surgical, St. Louis, MO. The Microsurgery Advanced Design Laboratory (MADLAB) may receive royalties related to the sale of this and other instruments mentioned in the article.Ophthalmology, 2002
- Sutureless Pars Plana Vitrectomy Through Self-sealing SclerotomiesArchives of Ophthalmology (1950), 1996