Determining Femoral Component Position Using CAS and Measured Resection
Open Access
- 1 November 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 466 (11) , 2745-2750
Abstract
To evaluate the ability of computer-assisted surgery (CAS) to accurately size and determine rotational alignment of the femoral component in TKA, the author reviewed femoral component position after 50 consecutive primary TKAs using a femur-first, measured resection workflow. The computer software used allowed femoral rotation to be selected based on epicondylar axis, posterior condylar axis, or anteroposterior axis. The final femoral component size and position was determined by the surgeon to avoid anterior notching, match the posterior-medial condyle resection, and flexed to match the plane of the anterior femoral cortex. Femoral sizing was confirmed intraoperatively with a standard sizing guide. The femoral component was downsized in 52% of patients from the size recommended by the computer software. The posterior condylar axis matched the implanted rotational position of the femoral component to within 1° in 64% of patients in contrast to the epicondylar axis (32%) and anteroposterior axis (26%). CAS provides information to make surgical decisions but does not replace clinical judgment. Landmark referencing may be compromised by limited surgical exposures leading to variation in implant positioning by computer software. A clear understanding of the principles of TKA is critical when using CAS to optimize implant sizing and position.Keywords
This publication has 43 references indexed in Scilit:
- Alignment and orientation of the components in total knee replacement with and without navigation supportThe Journal of Bone and Joint Surgery. British volume, 2007
- Leg Axis After Computer-Navigated Total Knee ArthroplastyThe Journal of Arthroplasty, 2005
- Navigation Improves Accuracy of Rotational Alignment in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2004
- Computer-assisted total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2004
- Computer-assisted knee arthroplasty versus a conventional jig-based techniqueThe Journal of Bone and Joint Surgery. British volume, 2004
- Low reproducibility of the intra–operative measurement of the transepicondylar axis during total knee replacementActa Orthopaedica, 2004
- Femoral Rotational Alignment Using the Tibial Shaft Axis in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1996
- Rotational Landmarks and Sizing of the Distal Femur in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1996
- Patellar Prosthesis Positioning in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1988
- Total Joint Arthroplasty of the KneeClinical Orthopaedics and Related Research, 1985