Pseudo-T2 mapping for normalization of T2-weighted prostate MRI
Open Access
- 12 February 2022
- journal article
- research article
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 35 (4) , 573-585
Abstract
Objective: Signal intensity normalization is necessary to reduce heterogeneity in T2-weighted (T2W) magnetic resonance imaging (MRI) for quantitative analysis of multicenter data. AutoRef is an automated dual-reference tissue normalization method that normalizes transversal prostate T2W MRI by creating a pseudo-T2 map. The aim of this study was to evaluate the accuracy of pseudo-T2s and multicenter standardization performance for AutoRef with three pairs of reference tissues: fat/muscle (AutoRefF), femoral head/muscle (AutoRefFH) and pelvic bone/muscle (AutoRefPB). Materials and methods: T2s measured by multi-echo spin echo (MESE) were compared to AutoRef pseudo-T2s in the whole prostate (WP) and zones (PZ and TZ/CZ/AFS) for seven asymptomatic volunteers with a paired Wilcoxon signed-rank test. AutoRef normalization was assessed on T2W images from a multicenter evaluation set of 1186 prostate cancer patients. Performance was measured by inter-patient histogram intersections of voxel intensities in the WP before and after normalization in a selected subset of 80 cases. Results: AutoRefFH pseudo-T2s best approached MESE T2s in the volunteer study, with no significant difference shown (WP: p = 0.30, TZ/CZ/AFS: p = 0.22, PZ: p = 0.69). All three AutoRef versions increased inter-patient histogram intersections in the multicenter dataset, with median histogram intersections of 0.505 (original data), 0.738 (AutoRefFH), 0.739 (AutoRefF) and 0.726 (AutoRefPB). Discussion: All AutoRef versions reduced variation in the multicenter data. AutoRefFH pseudo-T2s were closest to experimentally measured T2s.Keywords
Funding Information
- Ministry of Science and Technology, Taiwan (MOST 109-2628-B-182A-007)
- National Health Research Institutes (NHRI-109BCCO-MF-202009-02)
- Chang Gung Medical Foundation (CLRPG3K0022, CPRPG3G0023)
- The Research Council of Norway (295013)
- The Liaison Committee between the Central Norway Regional Health Authority and the Norwegian University of Science and Technology (90265300)
- Norges Teknisk-Naturvitenskapelige Universitet
- the Liaison Committee for Education, Research and Innovation in Central Norway (905481)
- NTNU Norwegian University of Science and Technology
This publication has 49 references indexed in Scilit:
- AcceleratedT2mapping for characterization of prostate cancerMagnetic Resonance in Medicine, 2011
- Aging and BoneJournal of Dental Research, 2010
- Breathhold multiecho fast spin‐echo pulse sequence for accurate R2 measurement in the heart and liverMagnetic Resonance in Medicine, 2009
- User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliabilityNeuroImage, 2006
- T1, T2 relaxation and magnetization transfer in tissue at 3TMagnetic Resonance in Medicine, 2005
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- New variants of a method of MRI scale standardizationIEEE Transactions on Medical Imaging, 2000
- Sources of intensity nonuniformity in spin echo images at 1.5 TMagnetic Resonance in Medicine, 1994
- Analysis of Carr—Purcell Spin-Echo NMR Experiments on Multiple-Spin Systems. II. The Effect of Chemical ExchangeThe Journal of Chemical Physics, 1966
- Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance ExperimentsPhysical Review B, 1954