Development of Radiofrequency Ablation Generator and Balloon-Based Catheter for Microendoluminal Thin-Layer Ablation Therapy Using the Rat Duodenum as a Model of Low-Impedance Tissue
Authors:
Open Access
- 23 September 2021
- journal article
- research article
- Published by Hindawi Limited in Journal of Healthcare Engineering
- Vol. 2021, 1-12
Abstract
Radiofrequency ablation (RFA) is a routinely used, safe, and effective method for the tissue destruction. Often, in case of its application in malignant conditions, the extent of tissue destruction is insufficient due to the size of the target lesion, as well as due to the risk of heat-induced damage to the surrounding organs. Nevertheless, there are conditions requiring superficial precise-depth ablation with preservation of deeper layers. These are represented, for example, by mucosal resurfacing in case of Barretts esophagus or treatment of recurrent mucosal bleeding in case of chronic radiation proctitis. Recently, new indications for intraluminal RFA use emerged, especially in the pancreatobiliary tract. In the case of intraductal use of RFA (e.g., biliary and pancreatic tract), there are currently available rigid and needle tip catheters. An expandable balloon-based RFA catheter suitable for use in such small-diameter tubular organs could be of benefit due to possible increase of contact between the probe and the target tissue; however, to prevent excessive tissue damage, a compatible generator suitable for low-impedance catheter/tissue is essential. This project aimed to develop a radiofrequency ablation generator and bipolar balloon-based catheter optimized for the application in the conditions of low-impedance tissue and (micro)endoluminal environment. Subsequent evaluation of biological effect in vivo was performed using duodenal mucosa in Wistar rat representing conditions of endoluminal radiofrequency ablation of low-impedance tissue. Experiments confirming the safety and feasibility of RFA with our prototype devices were conducted.Keywords
Funding Information
- Charles University (1042317)
This publication has 35 references indexed in Scilit:
- Endoscopic Duodenal–Jejunal Bypass Liner Rapidly Improves Type 2 DiabetesObesity Surgery, 2013
- Small Intestinal Alterations in Severely Obese Hyperglycemic SubjectsThe Journal of Clinical Endocrinology & Metabolism, 2011
- Histopathology Procedures: From Tissue Sampling to Histopathological Evaluation2010
- High-fat feeding stimulates endocrine, glucose-dependent insulinotropic polypeptide (GIP)-expressing cell hyperplasia in the duodenum of Wistar ratsDiabetologia, 2010
- Feasibility and safety of radiofrequency ablation for locally advanced pancreatic cancerBritish Journal of Surgery, 2010
- Liver ablation techniques: a reviewSurgical Endoscopy, 2009
- The Mechanism of Diabetes Control After Gastrointestinal Bypass Surgery Reveals a Role of the Proximal Small Intestine in the Pathophysiology of Type 2 DiabetesAnnals of Surgery, 2006
- Circumferential Pulmonary-Vein Ablation for Chronic Atrial FibrillationNew England Journal of Medicine, 2006
- Thin-layer ablation of human esophageal epithelium using a bipolar radiofrequency balloon deviceSurgical Endoscopy, 2005
- Percutaneous Radiofrequency Ablation of Malignancies in the LungAmerican Journal of Roentgenology, 2000