Multicenter Comparison of BACTEC 9050 and BACTEC 9240 Blood Culture Systems
- 1 June 1998
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 36 (6) , 1601-1603
Abstract
The overall recovery of organisms and time to detection with the BACTEC 9050 and BACTEC 9240 systems were compared in a multicenter evaluation. In the first phase of the study, a total of 4,383 compliant aerobic (Plus Aerobic/F) blood culture sets were processed. There was no significant difference in the recovery of individual groups of organisms with the two systems, with the exception of Streptococcus pneumoniae which was isolated more frequently with BACTEC 9050. False-positive signals occurred more often with BACTEC 9240 (58 cultures) than with BACTEC 9050 (43 cultures), but false-negative cultures were uncommon with both systems (3 cultures for each system). Time to detection of positive cultures of clinically significant organisms was essentially the same with both instruments. In the second phase of the study, 2,431 compliant anaerobic (Plus Anaerobic/F) blood culture sets were processed. There was no significant difference in the recovery of organisms with BACTEC 9050 compared with BACTEC 9240. Significantly ( P < 0.03) more false-positive signals occurred with BACTEC 9240 (15 cultures) than with BACTEC 9050 (4 cultures). Likewise, more false-negative cultures occurred with BACTEC 9240 (11 cultures) than with BACTEC 9050 (8 cultures). Time to detection of positive cultures of clinically significant organisms was essentially the same with both systems with the exception of anaerobes ( N = 10), which were recovered earlier ( P < 0.01) with BACTEC 9240 (35.0 h) than with BACTEC 9050 (61.4 h).Keywords
This publication has 6 references indexed in Scilit:
- Clinical comparison of BACTEC 9240 plus aerobic/F resin bottles and the isolator aerobic culture system for detection of bloodstream infectionsJournal of Clinical Microbiology, 1997
- Controlled clinical laboratory comparison of BACTEC plus aerobic/F resin medium with BacT/Alert aerobic FAN medium for detection of bacteremia and fungemiaJournal of Clinical Microbiology, 1997
- Controlled clinical evaluation of BACTEC Plus Aerobic/F and BacT/Alert Aerobic FAN bottles for detection of bloodstream infectionsJournal of Clinical Microbiology, 1995
- Controlled clinical comparison of Isolator and BACTEC 9240 Aerobic/F resin bottle for detection of bloodstream infectionsJournal of Clinical Microbiology, 1995
- Comparison of BACTEC 9240 and BacT/Alert blood culture systems in an adult hospitalJournal of Clinical Microbiology, 1995
- Multicenter clinical evaluation of a continuous monitoring blood culture system using fluorescent-sensor technology (BACTEC 9240)Journal of Clinical Microbiology, 1993