Different venous angioplasty manoeuvres for successful implantation of CRT devices
Authors:
- 18 December 2008
- journal article
- research article
- Published by Springer Nature in Clinical Research in Cardiology
- Vol. 98 (3) , 159-164
Abstract
Aims Cardiac resynchronization therapy (CRT) has growing impact in the treatment of severe heart failure Stenosis of coronary veins, complex structure of coronary sinus and occlusions of subclavian veins can limit lead passage in the target vein. Methods and Results Retrospective analysis of 705 implantation procedures of CRT devices from 1999 to July 2007 in a single centre to show the impact of venous angioplasty manoeuvres for successful placement of left ventricular lead. In 31 patients (3.5%) venous angioplasty was performed for LV-lead placement: 24 coronary veins (balloons 2.5–4.0mm), 4 subclavian veins, 3 valves in the coronary sinus and one Marshall vein were dilated. Ring like strictures of coronary veins made high inflation pressures (16 ± 4 atm) necessary. Success rate of LV lead placement were 99%. Complications were rare. Conclusions Angioplasty of coronary or subclavian veins and valve structures of coronary sinus are a useful and safe tool for successful lead placement. The use of balloons of 3.0mm in size usually allows implantation of at least a unipolar lead.Keywords
This publication has 13 references indexed in Scilit:
- First experience with a new active fixation coronary sinus leadEP Europace, 2007
- Detection of a persistent left superior vena cava by echocardiography, computed tomography, and magnetic resonance imagingClinical Research in Cardiology, 2007
- Implantation of Active Fixation Leads in Coronary Veins for Left Ventricular Stimulation: Report of Five CasesPacing and Clinical Electrophysiology, 2007
- Cardiac Resynchronization Therapy in Patients With a Narrow QRS ComplexJACC, 2006
- Effect of Percutaneous Interventions within the Coronary Sinus on the Success Rate of the Implantations of Resynchronization PacemakersPacing and Clinical Electrophysiology, 2006
- Leitlinien zur HerzschrittmachertherapieClinical Research in Cardiology, 2005
- Placement of Transvenous Pacemaker and ICD Leads Across Total Chronic OcclusionsPacing and Clinical Electrophysiology, 2005
- ACC/AHA 2005 Guideline Update for the Diagnosis and Management of Chronic Heart Failure in the Adult—Summary ArticleJACC, 2005
- The Coronary Venous AnatomyJACC, 2005
- Coronary vein balloon angioplasty forleft ventricular pacemaker lead implantationJACC, 2002