Sites With Small Impedance Decrease During Catheter Ablation for Atrial Fibrillation Are Associated With Recovery of Pulmonary Vein Conduction
- 3 October 2016
- journal article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 27 (12) , 1390-1398
Abstract
Impedance Decrease During AF Ablation: Objective: To correlate impedance decrease during atrial fibrillation (AF) ablation with lesion durability and PV conduction recovery demonstrated during redo procedures.Background: Markers of successful ablation beyond acute conduction block are needed to improve durability of pulmonary vein (PV) isolation (PVI). Local impedance decrease resulting from ablation is a real‐time marker of tissue heating and is correlated with lesion creation.Methods: Impedance changes associated with point‐by‐point radiofrequency ablation in the PV antra were recorded during 167 consecutive first‐time AF ablations. During clinically indicated redo procedures, sites of recovered PV conduction were identified, and were correlated with the impedance change achieved during ablation at these locations during the initial procedure.Results: Redo procedures were performed in 28 patients, in whom 19 sites of recovered PV conduction were documented. Most sites of PV reconnection (58%) occurred along the posterior PV antra. Ablation resulting in impedance decrease <10 ohms during the initial procedure was present in 89% (17/19) of sites with conduction recovery. Regions with adjacent ablation resulting in impedance decrease <10 ohms were associated with a higher rate of conduction recovery (37% vs. 1.5%, P < 0.001). Likewise, patients with PV conduction recovery demonstrated during redo procedure (Group 1) had larger regions where ablation resulted in <10 ohm impedance decrease than patients without PV conduction recovery (Group 2) (21.9 ± 15.5 mm vs. 11.5 ± 2.1 mm, P < 0.01).Conclusion: Recovered PV conduction occurs predominantly in regions where adjacent ablation applications result in impedance decreases <10 ohms. Impedance‐guided ablation strategies may improve durability of PVI.Keywords
Funding Information
- Biosense Webster
- Boston Scientific Corporation
This publication has 19 references indexed in Scilit:
- In Vivo Contact Force Analysis and Correlation With Tissue Impedance During Left Atrial Mapping and Catheter Ablation of Atrial FibrillationCirculation: Arrhythmia and Electrophysiology, 2014
- Ablation Effect Indicated by Impedance Fall is Correlated with Contact Force Level During Ablation for Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2013
- Lumped Element Electrical Model based on Three Resistors for Electrical Impedance in Radiofrequency Cardiac Ablation: Estimations from Analytical Calculations and Clinical DataThe Open Biomedical Engineering Journal, 2013
- Benefit of Pulmonary Vein Isolation Guided by Loss of Pace Capture on the Ablation LineJACC, 2013
- Acute electrical isolation is a necessary but insufficient endpoint for achieving durable PV isolation: the importance of closing the visual gapEP Europace, 2012
- Impedance and Temperature Monitoring Improve the Safety of Closed‐Loop Irrigated‐Tip Radiofrequency AblationJournal of Cardiovascular Electrophysiology, 2007
- RF Catheter Ablation: Lessons on LesionsPacing and Clinical Electrophysiology, 2006
- Electrophysiological Findings During Ablation of Persistent Atrial Fibrillation With Electroanatomic Mapping and Double Lasso Catheter TechniqueCirculation, 2005
- Response of Atrial Fibrillation to Pulmonary Vein Antrum Isolation Is Directly Related to Resumption and Delay of Pulmonary Vein ConductionCirculation, 2005
- Impedance Monitoring During Radiofrequency Catheter Ablation in HumansPacing and Clinical Electrophysiology, 1992