Adaptive local contrast enhancement method for medical images displayed on a video monitor
Authors:
- Tsair KaoTKTsair Kao
- 1 March 2000
- journal article
- research article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 22 (2) , 79-87
Abstract
It is known that light-box luminance is an important factor in the detection of objects on radiographs. Existing methods for image contrast enhancement do not consider the luminance effect so that the enhancement may be inappropriate for the processed image displayed on a video monitor. Based on the properties of human visual system (HVS), an adaptive local contrast enhancement (ALCE) method was developed to enhance the medical image displayed on the video monitor by investigating the influence on human eyes of display luminance difference between a conventional light-box and a video monitor. The HVS model indicated parts of a radiograph unclear to human eyes at a given display luminance. By calculating the contrast of the image pixel by pixel, we found the parts of an image that are needed to be amplified at low display luminance and provided these parts with adequate enhancement. The processed image displayed on a video monitor was visually equivalent to the raw radiograph displayed on a light-box. A quantitative evaluation method of image quality assessment was used to compare the ALCE-processed image with others.Keywords
This publication has 13 references indexed in Scilit:
- Detection of small low-contrast objects in mammography: effect of viewbox masking and luminance.American Journal of Roentgenology, 1998
- Digital radiography and conventional imaging of the chest: a comparison of observer performance.American Journal of Roentgenology, 1994
- Adaptive image contrast enhancement based on human visual propertiesIEEE Transactions on Medical Imaging, 1994
- A Fully Automated Adaptive Unsharp Masking Technique in Digital Chest RadiographInvestigative Radiology, 1992
- The Effect of Image Processing on Chest Radiograph Interpretations in a PACS EnvironmentInvestigative Radiology, 1990
- Receiver operating characteristic analysis of chest image interpretation with conventional, laser-printed, and high-resolution workstation images.Radiology, 1990
- Comparison of 2048-line digital display formats and conventional radiographs: an ROC studyAmerican Journal of Roentgenology, 1989
- Detection of pneumothorax: comparison of digital and conventional chest imagingAmerican Journal of Roentgenology, 1989
- Evaluation of digital unsharp masking and local contrast stretching as applied to chest radiographsIEEE Transactions on Biomedical Engineering, 1988
- Digital and conventional chest images: observer performance with Film Digital Radiography System.Radiology, 1986