Total Emission Time Resolved Decay: a Method for Measurement and Resolution of Broad-Band Emission
- 6 July 2020
- journal article
- research article
- Published by Springer Nature in Journal of Fluorescence
- Vol. 30 (5) , 1085-1094
Abstract
This article reports a time-resolved fluorescence data acquisition technique termed as “Total Emission Time Resolved Decay” (TETRD). TETRD is recorded by using zero-order diffraction of emission grating in TCSPC instrument. TETRD decay curve has entire wavelength dependent decay information buried in it. Cut-off filters are used to avoid scattering contamination. Two existing approaches are used for analysing the interconnected TETRD data. (i) First, global analysis: for discretely decaying multiple components, TETRD dataset is analyzed using global analysis. The normalized pre-exponentials (αi) and relative amplitudes (fi) recovered from global analysis reflect the individual component emission more faithfully and resembles with steady-state spectral data as well. (ii) Second, stretched exponential fitting (StrEF): for continuous lifetime distribution systems, StrEF (I(t) = I0 exp[−(t/τ)1/h]) has been used to analyse TETRD data. The average lifetime (τ) of StrEF matches well with the average lifetime of multi-exponential fitting, the heterogeneity factor (h) of StrEF is an additional parameter, which informs about local heterogeneity in the system. It is shown that the lifetimes obtained with TETRD matches well with the lifetimes obtained using conventional time resolved emission spectra (TRES). TETRD holds advantage in rapid data acquisition and facilitates inclusion of another variable (like concentration, solvent composition, pH, excitation wavelength etc.) into experimental design. Further, with the use of an appropriate data analysis tool, the multi-component decay profiles can be resolved conveniently.Keywords
This publication has 35 references indexed in Scilit:
- Global analysis of Förster resonance energy transfer in live cells measured by fluorescence lifetime imaging microscopy exploiting the rise time of acceptor fluorescencePhysical Chemistry Chemical Physics, 2010
- Global fitting without a global model: Regularization based on the continuity of the evolution of parameter distributionsThe Journal of Chemical Physics, 2008
- Global and target analysis of time-resolved spectraBiochimica et Biophysica Acta (BBA) - Bioenergetics, 2004
- Stretched exponential distributions in nature and economy: “fat tails” with characteristic scalesThe European Physical Journal B, 1998
- Relaxation distributions of fluorescence decaysThe Journal of Physical Chemistry, 1991
- GLOBAL ANALYSIS OF FLUORESCENCE DECAY: APPLICATIONS TO SOME UNUSUAL EXPERIMENTAL AND THEORETICAL STUDIESPhotochemistry and Photobiology, 1986
- Excited-state proton transfer of equilenin and dihydroequilenin: interaction with bilayer vesiclesBiochemistry, 1986
- Time-resolved emission spectra, decay-associated spectra, and species-associated spectraThe Journal of Physical Chemistry, 1986
- Decay-associated fluorescence spectra and the heterogeneous emission of alcohol dehydrogenaseBiochemistry, 1982
- Analysis of two-state excited-state reactions. The fluorescence decay of 2-naphtholThe Journal of Physical Chemistry, 1979