Focal Plane Detectors for the Advanced Gamma-Ray Imaging System (AGIS)

Authors:

Abstract
The Advanced Gamma‐Ray ImagingSystem (AGIS) is a concept for the next generation observatory in ground‐based very high energy gamma‐ray astronomy. Design goals are ten times better sensitivity, higher angular resolution, and a lower energy threshold than existing Cherenkov telescopes. Simulations show that a substantial improvement in angular resolution may be achieved if the pixel diameter is reduced to the order of 0.05 deg, i.e. two to three times smaller than the pixel diameter of current Cherenkov telescopecameras. At these dimensions, photondetectors with smaller physical dimensions can be attractive alternatives to the classical photomultiplier tube (PMT). Furthermore, the operation of an experiment with the size of AGIS requires photondetectors that are among other things more reliable, more durable, and possibly higher efficiency photondetectors. Alternative photondetectors we are considering for AGIS include both silicon photomultipliers (SiPMs) and multi‐anode photomultipliers (MAPMTs). Here we present results from laboratory testing of MAPMTs and SiPMs along with results from the first incorporation of these devices into cameras on test bed Cherenkov telescopes.