Abstract
Background: Dosimetry after radiopharmaceutical therapy with 177Lu (177Lu-RPT) relies on quantitative SPECT/CT imaging, for which suitable reconstruction protocols are required. In this study, we characterized for the first time the quantitative performance of a ring-shaped CZT-based camera using two different reconstruction algorithms: an ordered subset expectation maximization (OSEM) and a block sequential regularized expectation maximization (BSREM) combined with noise reduction regularization. This study lays the foundations for the definition of a reconstruction protocol enabling accurate dosimetry for patients treated with 177Lu-RPT. Methods: A series of 177Lu-filled phantoms were acquired on a StarGuide™ (GE HealthCare), with energy and scatter windows centred at 208 (± 6%) keV and 185 (± 5%) keV, respectively. Images were reconstructed with the manufacturer implementations of OSEM (GE-OSEM) and BSREM (Q.Clear) algorithms, and various combinations of iterations and subsets. Additionally, the manufacturer-recommended Q.Clear-based reconstruction protocol was evaluated. Quantification accuracy, measured as the difference between the SPECT-based and the radionuclide calibrator-based activity, and noise were evaluated in a large cylinder. Recovery coefficients (RCs) and spatial resolution were assessed in a NEMA IEC phantom with sphere inserts. The reconstruction protocols considered suitable for clinical applications were tested on a cohort of patients treated with [177Lu]Lu-PSMA-I&T. Results: The accuracy of the activity from the cylinder, although affected by septal penetration, was < 10% for all reconstructions. Both algorithms featured improved spatial resolution and higher RCs with increasing updates at the cost of noise build-up, but Q.Clear outperformed GE-OSEM in reducing noise accumulation. When the reconstruction parameters were carefully selected, similar values for noise (~0.15), spatial resolution (~1 cm) and RCs were found, irrespective of the reconstruction algorithm. Analogue results were found in patients. Conclusions: Accurate activity quantification is possible when imaging 177Lu with StarGuide™. However, the impact of septal penetration requires further investigations. GE-OSEM is a valid alternative to the recommended Q.Clear reconstruction algorithm, featuring comparable performances assessed on phantoms and patients.Keywords
Funding Information
- L'Association Jules Bordet
This publication has 27 references indexed in Scilit:
- Prospective observational study of 177Lu-DOTA-octreotate therapy in 200 patients with advanced metastasized neuroendocrine tumours (NETs): feasibility and impact of a dosimetry-guided study protocol on outcome and toxicityEuropean Journal of Nuclear Medicine and Molecular Imaging, 2018
- Quantitative accuracy of 177Lu SPECT imaging for molecular radiotherapyPLOS ONE, 2017
- Accuracy and precision assessment for activity quantification in individualized dosimetry of 177Lu-DOTATATE therapyEJNMMI Physics, 2017
- Phase 3 Trial of 177Lu-Dotatate for Midgut Neuroendocrine TumorsThe New England journal of medicine, 2017
- Accuracy of 177Lu activity quantification in SPECT imaging: a phantom studyEJNMMI Physics, 2017
- Gamma camera calibration and validation for quantitative SPECT imaging with 177LuApplied Radiation and Isotopes, 2016
- The evidence base for the use of internal dosimetry in the clinical practice of molecular radiotherapyEuropean Journal of Nuclear Medicine and Molecular Imaging, 2014
- MIRD Pamphlet No. 23: Quantitative SPECT for Patient-Specific 3-Dimensional Dosimetry in Internal Radionuclide TherapyJournal of Nuclear Medicine, 2012
- Globally convergent image reconstruction for emission tomography using relaxed ordered subsets algorithmsIEEE Transactions on Medical Imaging, 2003
- A concave prior penalizing relative differences for maximum-a-posteriori reconstruction in emission tomographyIEEE Transactions on Nuclear Science, 2002