Fixation with Bioabsorbable Pins in Chevron Bunionectomy*

Authors:
  • DMDavid F. Martin
    David F. Martin
  • JCJames M. Coumas
    James M. Coumas
  • GKGary M. Kiebzak
    Gary M. Kiebzak

Abstract
To be associated with osteolysis and formation of a sinus with a sterile discharge. We studied the outcome and complications seen with use of poly-p-dioxanone pins and those seen with use of stainless-steel Kirschner wires after chevron bunionectomy in 114 patients (144 feet). We found no difference between the treatment groups with regard to the prevalence of complications or the stability of fixation. Notably, the prevalence of osteolysis was quite similar between the treatment groups; none of the feet that had had fixation with bioabsorbable pins had formation of a sinus with a sterile discharge. We believe that bioabsorbable pins can be used reliably to fix the site of the osteotomy for a distal chevron bunionectomy without undue risk of osteolysis or other complications....

This publication has 32 references indexed in Scilit: