Adaptive velocity‐dependent proportional‐integral controller for high‐speed atomic force microscopy
Authors:
- 30 May 2019
- journal article
- research article
- Published by Wiley in Journal of Microscopy
- Vol. 275 (2) , 107-114
Abstract
Summary: High‐speed atomic force microscopy (AFM) has been rapidly developed in recent years. To reduce the oscillation of the scanner, a single‐tone sinusoidal wave is widely used as a scanning wave rather than a triangular wave in high‐speed AFM. However, the sinusoidal wave is nonlinear, resulting in a nonconstant relative linear velocity between the sample and the tip while scanning in the x‐direction. If a traditional proportional‐integral controller is still used as a feedback controller in the z‐direction, the control errors will be enormous. Therefore, the paper proposes a new adaptive velocity‐dependent proportional‐integral controller. The relationship between the proportional‐integral parameters and the linear velocity is achieved by fitting the experimental results. The adaptive and traditional controllers are compared against each other in some examples. The experiments demonstrate that the adaptive controller decreases the control errors in the z‐direction to a half, which provides more precise AFM images.Lay Description: Typically, the scanner follows a triangular waveform in fast axis (x‐axis), and follows a very slow ramp signal in the slow axis (y‐axis) of conventional AFM. This scanning mode can be called raster scan. However, the triangular waveform contains high‐order Fourier harmonics, vibrating the scanner and distorting the image easily. In high‐speed AFM, the effect of the high‐order Fourier harmonics will be more severe. The above problems can be solved by replacing triangular waves with single‐tone sinusoidal waveform. Therefore, the sinusoidal‐raster scan and nonraster scan based on the sinusoidal waveform are widely used in high‐speed atomic force microscopy.However, the nonlinearly scan path will cause a variable relative linear velocity between the sample and the tip. If a standard proportional‐integral controller is still used as a feedback controller in Z direction, the control errors will be large, and this difference will be evident at high‐speed scanning. Thus, the paper proposes a new adaptive velocity‐dependent proportional‐integral controller to solve this problem. Experiments show that the control errors obtained by using the adaptive controller is about a half of that without using it. These illustrate that the proposed method can improve the image quality of the AFM at both low and high scan speeds.Keywords
Funding Information
- Natural Science Foundation of Tianjin Municipality (18JCQNJC05600)
- National Natural Science Foundation of China (61204117)
This publication has 25 references indexed in Scilit:
- Development of an improved Kelvin probe force microscope for accurate local potential measurements on biased electronic devicesJournal of Microscopy, 2017
- Filming Biomolecular Processes by High-Speed Atomic Force MicroscopyChemical Reviews, 2014
- Sinusoidal trajectory for atomic force microscopy precision local scanning with auxiliary optical microscopy2013
- High-speed Lissajous-scan atomic force microscopy: Scan pattern planning and control design issuesReview of Scientific Instruments, 2012
- Bridging the gap between conventional and video-speed scanning probe microscopesUltramicroscopy, 2010
- Optimal Periodic Trajectories for Band-Limited SystemsIEEE Transactions on Control Systems Technology, 2009
- High-speed atomic force microscopy for nano-visualization of dynamic biomolecular processesProgress in Surface Science, 2008
- Image-based compensation of dynamic effects in scanning tunnelling microscopesNanotechnology, 2005
- Creep, Hysteresis, and Vibration Compensation for Piezoactuators: Atomic Force Microscopy ApplicationJournal of Dynamic Systems, Measurement, and Control, 1999
- Atomic Force MicroscopePhysical Review Letters, 1986