Moisture Effect on Polyether and Polyvinylsiloxane Dimensional Accuracy and Detail Reproduction
Authors:
- Mary P. WalkerMWMary P. Walker
- Cynthia S. PetrieCPCynthia S. Petrie
- Reem Haj‐AliRHReem Haj‐Ali
- Paulette SpencerPSPaulette Spencer
- Chris DumasCDChris Dumas
- 27 September 2005
- journal article
- research article
- Published by Wiley in Journal of Prosthodontics
- Vol. 14 (3) , 158-163
Abstract
Purpose: This investigation evaluated and compared the dimensional accuracy and surface detail reproduction of two hydrophilic polyvinylsiloxane (PVS) and two polyether (PE) impression materials when used under dry and moist conditions. Methods: Impressions were made of stainless steel dies as described in ANSI/ADA specification no. 19, with two vertical and three horizontal lines inscribed on the die superior surface. Impressions were made under dry and moist conditions (17 impressions per condition for each material). Dimensional accuracy was measured by comparing the average length of the middle horizontal line in each impression with the same line on the metal die using a measuring microscope with an accuracy of 0.001 mm. Surface detail reproduction was evaluated by using criteria similar to ADA specification no. 19: continuous replication of at least two of the three horizontal lines. Results: The mean percent dimensional change and SD values ranged from −0.135% (0.035) to 0.053% (0.031). A two‐way analysis of variance (ANOVA) indicated that moisture did not cause significant adverse effects on the dimensional accuracy of any material (p > 0.05); however, significant differences were found between the materials (p < .05). The surface detail evaluation indicated that moisture had a significant effect on detail reproduction of PVS materials (Pearson's Chi square, p < 0.05). Under dry conditions, all materials produced satisfactory detail reproduction 100% of the time; however, under moist conditions, only 29% of Aquasil and Genie Ultra PVS impressions produced satisfactory detail reproduction, while 100% of Permadyne Garant and Impregum Penta Soft PE impressions still met the surface detail criteria. Conclusions: Although moisture may not adversely affect the dimensional accuracy of either PE or hydrophilic PVS material, the evidence suggests that PE material is more likely to produce impressions with superior detail reproduction in the presence of moisture.Keywords
This publication has 13 references indexed in Scilit:
- The effect of surface moisture on detail reproduction of elastomeric impressionsThe Journal of Prosthetic Dentistry, 2003
- Polyvinyl siloxane impression materials: An update on clinical useAustralian Dental Journal, 1998
- Evaluation of detail reproduction for three die materials by using scanning electron microscopy and two-dimensional profilometryThe Journal of Prosthetic Dentistry, 1995
- Polyvinyl siloxane impression materials: A review of properties and techniquesThe Journal of Prosthetic Dentistry, 1992
- Laboratory assessment of impression accuracy by clinical simulationJournal of Dentistry, 1992
- Dentin surface reproduction with hydrophilic and hydrophobic impression materialsDental Materials, 1991
- Detail reproduction of soft tissue: A comparison of impression materialsThe Journal of Prosthetic Dentistry, 1991
- The relationship between contact angles of die stone on elastomeric impression materials and voids in stone castsDental Materials, 1990
- Wettability of a hydrophilic addition silicone impression materialThe Journal of Prosthetic Dentistry, 1989
- Revised American Dental Association Specification No. 19 for Non-Aqueous, Elastomeric Dental Impression MaterialsThe Journal of the American Dental Association, 1977