A statistical approach to quantification of genetically modified organisms (GMO) using frequency distributions
Open Access
- 14 December 2014
- journal article
- research article
- Published by Springer Nature in BMC Bioinformatics
- Vol. 15 (1) , 407
Abstract
According to Regulation (EU) No 619/2011, trace amounts of non-authorised genetically modified organisms (GMO) in feed are tolerated within the EU if certain prerequisites are met. Tolerable traces must not exceed the so-called ‘minimum required performance limit’ (MRPL), which was defined according to the mentioned regulation to correspond to 0.1% mass fraction per ingredient. Therefore, not yet authorised GMO (and some GMO whose approvals have expired) have to be quantified at very low level following the qualitative detection in genomic DNA extracted from feed samples. As the results of quantitative analysis can imply severe legal and financial consequences for producers or distributors of feed, the quantification results need to be utterly reliable. We developed a statistical approach to investigate the experimental measurement variability within one 96-well PCR plate. This approach visualises the frequency distribution as zygosity-corrected relative content of genetically modified material resulting from different combinations of transgene and reference gene Cq values. One application of it is the simulation of the consequences of varying parameters on measurement results. Parameters could be for example replicate numbers or baseline and threshold settings, measurement results could be for example median (class) and relative standard deviation (RSD). All calculations can be done using the built-in functions of Excel without any need for programming. The developed Excel spreadsheets are available (see section ‘Availability of supporting data’ for details). In most cases, the combination of four PCR replicates for each of the two DNA isolations already resulted in a relative standard deviation of 15% or less. The aims of the study are scientifically based suggestions for minimisation of uncertainty of measurement especially in —but not limited to— the field of GMO quantification at low concentration levels. Four PCR replicates for each of the two DNA isolations seem to be a reasonable minimum number to narrow down the possible spread of results.Keywords
This publication has 12 references indexed in Scilit:
- A calibrator plasmid for quantitative analysis of insect resistant maize (Yieldgard MON 810)Food Chemistry, 2013
- Quantitative Analysis of Food and Feed Samples with Droplet Digital PCRPLOS ONE, 2013
- Development of a CTAB buffer-based automated gDNA extraction method for the surveillance of GMO in seedEuropean Food Research and Technology, 2013
- In-depth analysis of the endogenous reference genes used in the quantitative PCR detection systems for riceEuropean Food Research and Technology, 2012
- Four new SYBR®Green qPCR screening methods for the detection of Roundup Ready®, LibertyLink®, and CryIAb traits in genetically modified productsEuropean Food Research and Technology, 2011
- Validation of a newly developed hexaplex real-time PCR assay for screening for presence of GMOs in food, feed and seedAnalytical and Bioanalytical Chemistry, 2010
- Comparison of different real-time PCR chemistries and their suitability for detection and quantification of genetically modified organismsBMC Biotechnology, 2008
- Cloned plasmid DNA fragments as calibrators for controlling GMOs: different real-time duplex quantitative PCR methodsAnalytical and Bioanalytical Chemistry, 2003
- Roundup Ready ® soybean event-specific real-time quantitative PCR assay and estimation of the practical detection and quantification limits in GMO analysesEuropean Food Research and Technology, 2001
- Mathematisch-statistische Methoden in der praktischen AnwendungJournal of Pest Science, 1971