Electrospun porous La–Sr–Co–Ni–O nanofibers for highly sensitive non-enzymatic glucose detection
Open Access
- 11 January 2022
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Materials Advances
- Vol. 3 (4) , 2096-2103
Abstract
Glucose biosensors are widely used for clinical, industrial, and environmental applications. Nonenzymatic electrochemical glucose biosensors based on metal oxides with a perovskite structure have exhibited high sensitivity, excellent stability, and cost efficiency. In this work, porous La-Sr-Co-Ni-O (LSCNO) nanofibers, with an ABO3-type perovskite structure, were prepared through optimizing the A-site and B-site elements by electrospinning, followed with calcination at 700 ○C for 5 h. Characterized by scanning and transmission electron microscopy, X-ray diffraction, and X-ray photoelectron spectroscopy, fabricated nanofibers were confirmed to be porous and nanosized polycrystalline grains with high crystallinity. A novel La0.75Sr0.25Co0.5Ni0.5O3-based nonenzymatic electrochemical biosensor was developed, which is sensitive to glucose because of an electrochemically catalytic mechanism, a mediated electron transfer involving Ni(II)/Ni(III) or Co(II)/Co(III), accompanying with gluconic acid acid complexation. The glucose biosensor presented linear response in the range of 0.1-1.0 mM with a calibration sensitivity of 924±28 µA/mM, a proportion of the variance of 0.9926, and a lower limit of detection of 0.083 mM, respectively, demonstrating an outstanding analytical performance that may be appropriate to blood test. The biosensor showed no response to the most widely used anionic surfactant, sodium dodecyl sulfate, but was linearly responsive to other biomolecules, such as fructose, lactose, galactose, mannose, dopamine, and ascorbic acid. This novel nonenzymatic electrochemical biosensor has a potential to be an appealing sensor to the detection of multiple biomolecules.Keywords
Funding Information
- National Science Foundation (NSF EIR (ECCS 1900837), NSF PREM (1827731))
This publication has 41 references indexed in Scilit:
- Comparison and validation of 2 analytical methods for measurement of urinary sucrose and fructose excretionNutrition Research, 2013
- Structural characterization of nano-crystalline Co3O4 ultra-fine fibers obtained by sol–gel electrospinningJournal of Sol-Gel Science and Technology, 2013
- A novel sensitive nonenzymatic glucose sensor based on perovskite LaNi0.5Ti0.5O3-modified carbon paste electrodeSensors and Actuators B: Chemical, 2010
- Preparation of perovskite-type composite oxide LaNi0.5Ti0.5O3–NiFe2O4 and its application in glucose biosensorJournal of Electroanalytical Chemistry, 2010
- Electrochemical biosensorsChemical Society Reviews, 2010
- A symmetrical solid oxide fuel cell demonstrating redox stable perovskite electrodesJournal of Materials Chemistry, 2006
- DJ-1 Is a Redox-Dependent Molecular Chaperone That Inhibits α-Synuclein Aggregate FormationPLOS Biology, 2004
- Determination of total sugars in lignocellulose hydrolysate by a mediated Gluconobacter oxydans biosensorAnalytica Chimica Acta, 2000
- Electrooxidation of alcohols and sugars catalysed on a nickel oxide modified glassy carbon electrodeJournal of Electroanalytical Chemistry, 1995
- Glucose oxidase: an ideal enzymeBiosensors and Bioelectronics, 1992