Abstract
Proof-of-concept experimental results stemming from beam simulations for a microfocus electron gun are presented. The simulations demonstrate the potential to produce 4 mA of current through a 40-μm-diameter spot, at an energy of 30 keV, emitted from a 1-mm-diameter cathode with low energy spread and high brightness. The experimental realization, scaled down for practicality, but consistent with and confirming the higher-energy simulation, produced 2 μA of current with an approximately 28 μm spot size at an energy of 9.3 keV. The electrons originated from an Ar+-ion-treated reticulated vitreous carbon (RVC) field-emission cathode shaped as an approximately 1-mm-diameter disk. The primary application for this work is a highly monochromatic microfocus x-ray source for use in phase-contrast imaging, although other beam applications exist. The use of an Ar+-ion-irradiated RVC cathode allows high, stable current at low electric field, superior to what is achievable using field-emitter arrays or carbon-nanotube cathodes. This method, scaled up to its maximum potential, also enables a high-current-density microfocus beam, which, to date, has not been demonstrated using thermionic cathodes. Such a beam applied to an x-ray source for phase-contrast imaging represents a significant benefit in medical diagnostics.Keywords
This publication has 20 references indexed in Scilit:
- X-ray phase radiography and tomography of soft tissue using grating interferometryEuropean Journal of Radiology, 2008
- Robust and regenerable integrally gated carbon nanotube field emitter arraysJournal of Applied Physics, 2005
- Optical Performance of Carbon-Nanotube Electron SourcesPhysical Review Letters, 2005
- Novel cold cathode materials and applicationsMaterials Science and Engineering: R: Reports, 2005
- Clinical implementation of x‐ray phase‐contrast imaging: Theoretical foundations and design considerationsMedical Physics, 2003
- X-ray refraction effects: application to the imaging of biological tissuesBritish Journal of Radiology, 2003
- Vacuum Microelectronics2001
- Phase-Contrast Tomographic Imaging Using an X-ray InterferometerJournal of Synchrotron Radiation, 1998
- Phase-contrast imaging of weakly absorbing materials using hard X-raysNature, 1995
- Electron Gun Using a Field Emission SourceReview of Scientific Instruments, 1968