Whole-body dual-energy X-ray absorptiometry demonstrates better reliability than segmental body composition analysis in college-aged students
Authors:
Open Access
- 22 April 2019
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (4) , e0215599
Abstract
Dual-energy X-ray absorptiometry (DXA) is rapidly becoming more accessible and popular as a technique to monitor body composition. The reliability of DXA has been examined extensively using a number of different methodological approaches. This study sets up to investigate the accuracy of measuring the parameters of body composition (BC) by means of the whole-body and the segmental DXA method analysis with the typical error of measurement (TEM) that allows for expressing the error in the units of measure. The research was implemented in a group of 63 participants, all of whom were university students. Thirty-eight males (22.6±2.9 years, average body mass 77.5±8.4 kg) and 25 females (21.4±2.0 years, average body mass 58.6±7.2 kg) were recruited. The measured parameters included body mass (BM), fat-free mass (FFM), body fat (BF), bone mineral content (BMC), bone mineral density (BMD). For the whole-body analysis, the determined TEM was: BM at the level of 0.12 kg in females and 0.29 kg in males; BF 0.25kg and 0.44% females, 0.52 kg and 0.66% males; FFM 0.24 kg females and 0.42 kg males; BMC 0.02 kg females and males; BMD 0.01g/cm2 females and males. The TEM values in the segmental analysis were: BF within the range of 0.04–0.28 kg and 0.68–1.20% in females, 0.10–0.36 kg and 0.72–1.94% in males; FFM 0.08–0.41 kg females and 0.17–0.86 males, BMC 0.00–0.02 kg females and 0.01–0.02 kg males in relation to the body segment (upper limb, trunk, lower limb). The BMD value was at the level of 0.01–0.02g/cm2. The study results showed high reliability in measuring body composition parameters using the DXA method. The whole-body analysis showed a higher accuracy of measurement than the segmental. Only the changes that are greater than the TEM, or the upper bound (95%) of the confidence interval of the measurement can be considered demonstrable when interpreting repeated measurements.Keywords
Funding Information
- Ministerstvo Školství, Mládeže a Tělovýchovy (CZ.02.1.01/0.0/0.0/16_019/0000798)
- Univerzita Karlova v Praze (PROGRES Q41)
This publication has 50 references indexed in Scilit:
- Sport and Training Influence Bone and Body Composition in Women Collegiate AthletesJournal of Strength & Conditioning Research, 2010
- Strength and Functional Characteristics of Men and Women 65 Years and OlderRejuvenation Research, 2010
- Validity of Measuring Body Fat Using the Skinfold MethodMedicina Sportiva, 2009
- Body Segment Parameter Estimation of the Human Lower Leg Using an Elliptical Model with Validation from DEXAAnnals of Biomedical Engineering, 2006
- Instrument performance in bone density testing at five Australian centersAustralian and New Zealand Journal of Medicine, 1997
- Comparison of different models for interpreting bone mineral density measurements using DXA and MRI technologyBone, 1995
- Assessment of the composition of major body regions by dual‐energy X‐ray absorptiometry (DEXA), with special reference to limb muscle massClinical Physiology and Functional Imaging, 1992
- Validation of body composition by dual energy X‐ray absorptiometry (DEXA)Clinical Physiology and Functional Imaging, 1991
- The use of magnetic resonance imaging for measuring segment inertial propertiesJournal of Biomechanics, 1989
- Evaluation of cross-sectional geometry and mass density distributions of humans and laboratory animals using computerized tomographyJournal of Biomechanics, 1983