RF pulse amplifier for CVD-diamond particle detectors
Authors:
- 1 April 2021
- journal article
- research article
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 16 (04) , T04005
Abstract
This article introduces a design of a Low Noise Amplifier (LNA), for the field of diamond particle detectors. This amplifier is described from simulation to measurements, which include pulses from α particles detection. In hadron therapy, with high-frequency pulsed particle beams, the diamond detector is a promising candidate for beam monitoring and time-stamping, with prerequisite of fast electronics. The LNA is designed with surface mounted components and RF layout techniques to control costs and to allow timing performance suitable for sub-nanosecond edges of pulses. Also this amplifier offers the possibility of high voltage biasing, a characteristic essential for driving diamond detectors. Finally the greatest asset of this study is certainly the minimization of the power consumption, which allows us to consider designs with multiple amplifiers, in limited space, for striped diamond detectors.Keywords
All Related Versions
This publication has 5 references indexed in Scilit:
- The ATLAS Beam Conditions MonitorJournal of Instrumentation, 2008
- Radiation hardness evaluation of SiGe HBT technologies for the Front-End electronics of the ATLAS UpgradeNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007
- Performance of a fast low noise front-end preamplifier for the MAGIC imaging Cherenkov telescopeIEEE Transactions on Nuclear Science, 1999
- CMOS low noise amplifier for microstrip readout Design and resultsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1991
- A silicon surface barrier microstrip detector designed for high energy physicsNuclear Instruments and Methods, 1980