Ex vivo tracheomalacia model with 3D-printed external tracheal splint
Authors:
- 17 August 2016
- journal article
- research article
- Published by Wiley in The Laryngoscope
- Vol. 127 (4) , 950-955
Abstract
To design and evaluate an ex vivo model of tracheomalacia with and without a three-dimensional (3D)–printed external tracheal splint. Prospective, ex vivo animal trial. Three groups of ex vivo porcine tracheas were used: 1) control (unmanipulated trachea), 2) tracheomalacia (tracheal rings partially incised and crushed), and 3) splinted tracheomalacia (external custom tracheal splint fitted onto group 2 trachea). Each end of an ex vivo trachea was sealed with a custom-designed and 3D-printed cap; a transducer was placed through one end to measure the pressure inside the trachea. Although the negative pressure was applied to the tracheal lumen, the tracheal wall collapse was measured externally and internally using a bronchoscope. Each group had at least three recorded trials. Tracheal diameter was evaluated using ImageJ software (National Institutes of Health, Bethesda, MD) and was averaged between two raters. Average tracheal occlusion percentage was compared using Student t test. The average occlusion was 31% for group 1, 87.4% for group 2, and 20% for group 3. Significant differences were found between the control and tracheomalacia groups (P < 0.01) and the tracheomalacia and splinted tracheomalacia groups (P < 0.01). There was no significant difference between the control and splinted tracheomalacia groups (P = 0.13). Applied pressure was plotted against occlusion and regression line slope differed between the tracheomalacia (0.91) and control (0.12) or splinted tracheomalacia (0.39) groups. We demonstrate the potential for an ex vivo tracheomalacia model to reproduce airway collapse and show that this collapse can be treated successfully with a 3D-printed external splint. These results are promising and justify further studies. N/A. Laryngoscope, 2016Keywords
Funding Information
- Goody Two Shoes Foundation
This publication has 17 references indexed in Scilit:
- External bioresorbable airway rigidification to treat refractory localized tracheomalaciaThe Laryngoscope, 2016
- RETRACTED: Airway TransplantationThoracic Surgery Clinics, 2014
- Treatment of Severe Porcine Tracheomalacia With a 3-Dimensionally Printed, Bioresorbable, External Airway SplintJAMA Otolaryngology–Head & Neck Surgery, 2014
- RETRACTED: The first tissue-engineered airway transplantation: 5-year follow-up resultsThe Lancet, 2014
- Tracheomalacia/Tracheobronchomalacia and Hyperdynamic Airway CollapseImmunology and Allergy Clinics of North America, 2013
- Evaluation of the Structural Integrity and Extracellular Matrix Components of Tracheal Allografts Following Cyclical Decellularization Techniques: Comparison of Three ProtocolsTissue Engineering Part C: Methods, 2012
- The Compromised Airway: Tumors, Strictures, and TracheomalaciaSurgical Clinics of North America, 2010
- Airway Stabilization With Silicone Stents for Treating Adult TracheobronchomalaciaChest, 2007
- High Incidence of Tracheomalacia in Longstanding Goiters: Experience from an Endemic Goiter RegionWorld Journal of Surgery, 2007
- Tracheomalacia and Tracheobronchomalacia in Children and AdultsChest, 2005