Patient Blood Management in Elective Total Hip- and Knee-replacement Surgery (Part 1)
Authors:
- Cynthia So-OsmanCSCynthia So-Osman
- Rob G. H. H. NelissenRNRob G. H. H. Nelissen
- Ankie W. M. M. Koopman-Van GemertAGAnkie W. M. M. Koopman-Van Gemert
- Ewoud KluyverEKEwoud Kluyver
- Ruud G. PöllRPRuud G. Pöll
- Ron OnstenkRORon Onstenk
- Joost A. Van HiltenJHJoost A. Van Hilten
- Thekla M. Jansen-WerkhovenTJThekla M. Jansen-Werkhoven
- Wilbert B. van Den HoutWHWilbert B. van Den Hout
- Ronald BrandRBRonald Brand
- Anneke BrandABAnneke Brand
- 1 April 2014
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 120 (4) , 839-851
Abstract
Background: Patient blood management combines the use of several transfusion alternatives. Integrated use of erythropoietin, cell saver, and/or postoperative drain reinfusion devices on allogeneic erythrocyte use was evaluated using a restrictive transfusion threshold. Methods: In a factorial design, adult elective hip- and knee-surgery patients with hemoglobin levels 10 to 13 g/dl (n = 683) were randomized for erythropoietin or not, and subsequently for autologous reinfusion by cell saver or postoperative drain reinfusion devices or for no blood salvage device. Primary outcomes were mean allogeneic intra- and postoperative erythrocyte use and proportion of transfused patients (transfusion rate). Secondary outcome was cost-effectiveness. Results: With erythropoietin (n = 339), mean erythrocyte use was 0.50 units (U)/patient and transfusion rate 16% while without (n = 344), these were 0.71 U/patient and 26%, respectively. Consequently, erythropoietin resulted in a nonsignificant 29% mean erythrocyte reduction (ratio, 0.71; 95% CI, 0.42 to 1.13) and 50% reduction of transfused patients (odds ratio, 0.5; 95% CI, 0.35 to 0.75). Erythropoietin increased costs by €785 per patient (95% CI, 262 to 1,309), that is, €7,300 per avoided transfusion (95% CI, 1,900 to 24,000). With autologous reinfusion, mean erythrocyte use was 0.65 U/patient and transfusion rate was 19% with erythropoietin (n = 214) and 0.76 U/patient and 29% without (n = 206). Compared with controls, autologous blood reinfusion did not result in erythrocyte reduction and increased costs by €537 per patient (95% CI, 45 to 1,030). Conclusions: In hip- and knee-replacement patients (hemoglobin level, 10 to 13 g/dl), even with a restrictive transfusion trigger, erythropoietin significantly avoids transfusion, however, at unacceptably high costs. Autologous blood salvage devices were not effective.Keywords
This publication has 34 references indexed in Scilit:
- Detection, evaluation, and management of preoperative anaemia in the elective orthopaedic surgical patient: NATA guidelinesBritish Journal of Anaesthesia, 2011
- Activity‐based costs of blood transfusions in surgical patients at four hospitalsTransfusion, 2010
- Rationale for randomized controlled trials and for intention‐to‐treat analysis in transfusion medicine: are they one and the same?Vox Sanguinis, 2008
- A prospective randomised controlled trial of autologous retransfusion in total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2008
- Guidelines for policies on alternatives to allogeneic blood transfusion. 1. Predeposit autologous blood donation and transfusionTransfusion Medicine, 2007
- Blood use in elective surgery: the Austrian benchmark studyTransfusion, 2007
- Efficacy, safety and user‐friendliness of two devices for postoperative autologous shed red blood cell re‐infusion in elective orthopaedic surgery patients: a randomized pilot studyTransfusion Medicine, 2006
- A review of nearly two decades in an autologous blood programme: the rise and fall of activityTransfusion Medicine, 2006
- Autotransfusion drains in total knee replacement. Are they alternatives to homologous transfusion?International Orthopaedics, 2006
- Advantages of Using the Net-Benefit Approach for Analysing Uncertainty in Economic Evaluation StudiesPharmacoEconomics, 2003