Minimum Ignition Temperature of Wood Dust Layers
Open Access
- 1 June 2013
- journal article
- Published by Walter de Gruyter GmbH in Research Papers Faculty of Materials Science and Technology Slovak University of Technology
- Vol. 21 (Special-) , 127-131
Abstract
Fire characteristic (properties) are used to determine the fire risk and explosion hazard of materials. They are defined as numerical values which describe behavior in the process of burning. They can be determinate by standardized test methods. In this paper is described the most important fire technical characteristic of dust layer (minimum ignition temperature) and the results of standard laboratory method determination for wood dusts, aswell.Keywords
This publication has 4 references indexed in Scilit:
- Experimental Analysis of Minimal Ignition Temperatures of a Dust Layer and Clouds on a Heated Surface of Selected Flammable DustsProcedia Engineering, 2012
- Dust explosion incidents and regulations in the United StatesJournal of Loss Prevention in the Process Industries, 2007
- Ignition of a dust layer by a constant heat flux-heat transport in the layerJournal of Loss Prevention in the Process Industries, 2006
- Industrial Fire Protection Engineering2003