Frequency-Dependent Behavior of the Intervertebral Disc in Response to Each of Six Degree of Freedom Dynamic Loading
- 15 July 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Spine
- Vol. 33 (16) , 1731-1738
Abstract
Study Design. Nondestructive displacement-controlled dynamic testing of cadaver material, with repeated measures design and randomized sequence of tests. Objective. To determine whether the frequency-dependent changes in disc stiffness and phase angle between load and displacement differ between the 6 principal directions of displacement, and whether these differences are greater in deformation directions associated with greater intradiscal fluid flow. Summary of Background Data. Prior studies of time-dependent behavior of discs have focused on compression. Comparing different deformation directions allows effects of fluid flow to be distinguished from effects of the solid phase viscoelasticity. Methods. Vertebra-disc-vertebra preparations (N = 9) from human lumbar spines were subjected to each of 3 displacements and 3 rotations (6 degree of freedom) at each of 4 frequencies (0.001, 0.01, 0.1, and 1 Hz) after equilibration overnight under a 0.4 MPa preload in a bath of phosphate buffered saline at 37°C with protease inhibitors. The forces and torques were recorded along with the applied translation or rotation. The stiffness (force/displacement or torque/rotation) and the phase angle (between each force and displacement) were calculated for each degree of freedom from recorded data. Results. Disc stiffness increased linearly with the log-frequency. The increases over the four decades of frequency were 35%, 33%, and 26% for AP shear, lateral shear, and torsion respectively, and were 45%, 29%, 51%, and 83% for compression, lateral bending, flexion, and extension. The phase angle (a measure of energy absorption) averaged 6.2, 5.1, and 5.1 degrees in AP shear, lateral shear, and torsion, respectively, and 7.0, 7.0, and 8.6 degrees for compression, lateral bending, and flexion-extension. There were no consistent variations of phase angle with frequency. Conclusion. The stiffness increase and phase angle decrease with frequency were greater for deformation modes in which fluid flow effects are thought to be greater.Keywords
This publication has 36 references indexed in Scilit:
- Effect of displacement rate on the tensile mechanics of pediatric cervical functional spinal unitsJournal of Biomechanics, 2005
- Single lamellar mechanics of the human lumbar anulus fibrosusBiomechanics and Modeling in Mechanobiology, 2004
- An ionised/non-ionised dual porosity model of intervertebral disc tissueBiomechanics and Modeling in Mechanobiology, 2003
- Radial tensile properties of the lumbar annulus fibrosus are site and degeneration dependentJournal of Orthopaedic Research, 1997
- Tensile Properties of Nondegenerate Human Lumbar Anulus FibrosusSpine, 1996
- The mechanical properties of skeletally mature rabbit anterior cruciate ligament and patellar tendon over a range of strain ratesJournal of Orthopaedic Research, 1993
- Preliminary Evaluation of a Scheme for Grading the Gross Morphology of the Human Intervertebral DiscSpine, 1990
- The Apparent Viscoelastic Behavior of Articular Cartilage—The Contributions From the Intrinsic Matrix Viscoelasticity and Interstitial Fluid FlowsJournal of Biomechanical Engineering, 1986
- Temperature dependence of the tensile properties of interspinous ligaments of sheepJournal of Biomedical Engineering, 1986
- Biphasic Creep and Stress Relaxation of Articular Cartilage in Compression: Theory and ExperimentsJournal of Biomechanical Engineering, 1980