Solving intraocular lens–related pigment dispersion syndrome with repositioning of primary sulcus implanted single-piece IOL in the capsular bag
Authors:
- Thomas KohnenTKThomas Kohnen
- Daniel KookDKDaniel Kook
- 1 August 2009
- journal article
- case report
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 35 (8) , 1459-1463
Abstract
We describe 2 cases of pigment dispersion syndrome (PDS) after uneventful phacoemulsification and implantation of a posterior chamber single-piece intraocular lens (IOL) with a sharp-edge design. In both cases, several days after IOL implantation, marked pigment dispersion was seen on the iris and in the trabecular meshwork, associated with an elevation in intraocular pressure (IOP). Thorough examination showed that the implanted IOL was in the ciliary sulcus. After surgical repositioning of both IOLs in the capsular bag, the pigment dispersion regressed and the IOP returned to normal limits. The 2 cases suggest that particularly in PDS patients, an IOL with an anterior sharp-edge design should be implanted in the capsular bag. Implantation in the ciliary sulcus should be avoided.Keywords
This publication has 18 references indexed in Scilit:
- Optic Edge Design as Long-term Factor for Posterior Capsular Opacification RatesOphthalmology, 2008
- Sekundärer Augeninnendruckanstieg nach komplikationsloser Kataraktoperation mit HinterkammerlinsenimplantationDer Ophthalmologe, 2008
- Efficacy of Different Intraocular Lens Materials and Optic Edge Designs in Preventing Posterior Capsular Opacification: A Meta-AnalysisAmerican Journal of Ophthalmology, 2007
- Pigment dispersion with elevated intraocular pressure after acrysof intraocular lens implantation in the ciliary sulcusJournal of Cataract & Refractive Surgery, 2001
- Effect of trabecular aspiration on intraocular pressure in pigment dispersion syndrome and pigmentary glaucomaOphthalmology, 2000
- Iris chafing in pseudophakiaDocumenta Ophthalmologica, 1994
- Pigmentary dispersion syndrome subsequent IOL implantation in P.C.Documenta Ophthalmologica, 1989
- Pigment dispersion syndrome associated with silicone posterior chamber intraocular lensesJournal of Cataract & Refractive Surgery, 1988
- Evaluation of 50 silicone posterior chamber lens implantationsJournal of Cataract & Refractive Surgery, 1987
- Long-term Analysis of Pigmentary Dispersion Syndrome and Piegmentary GlaucomaOphthalmology, 1986