Abstract
Background: MRI is the imaging modality of choice for diagnosis and intervention assessment in neurological disease. Its full potential has not been realized due in part to challenges in harmonizing advanced techniques across multiple sites.Purpose: To develop a method for the assessment of reliability and repeatability of advanced multisite‐multisession neuroimaging studies and specifically to assess the reliability of an advanced MRI protocol, including multiband fMRI and diffusion tensor MRI, in a multisite setting.Study Type: Prospective.Population: Twice repeated measurement of a single subject with stable relapsing‐remitting multiple sclerosis (MS) at seven institutions.Field Strength/Sequence: A 3 T MRI protocol included higher spatial resolution anatomical scans, a variable flip‐angle longitudinal relaxation rate constant (R1 ≡ 1/T1) measurement, quantitative magnetization transfer imaging, diffusion tensor imaging, and a resting‐state fMRI (rsFMRI) series.Assessment: Multiple methods of assessing intrasite repeatability and intersite reliability were evaluated for imaging metrics derived from each sequence.Statistical Tests: Student's t‐test, Pearson's r, and intraclass correlation coefficient (ICC) (2,1) were employed to assess repeatability and reliability. Two new statistical metrics are introduced that frame reliability and repeatability in the respective units of the measurements themselves.Results: Intrasite repeatability was excellent for quantitative R1, magnetization transfer ratio (MTR), and diffusion‐weighted imaging (DWI) based metrics (r > 0.95). rsFMRI metrics were less repeatable (r = 0.8). Intersite reliability was excellent for R1, MTR, and DWI (ICC >0.9), and moderate for rsFMRI metrics (ICC∼0.4).Data Conclusion: From most reliable to least, using a new reliability metric introduced here, MTR > R1 > DWI > rsFMRI; for repeatability, MTR > DWI > R1 > rsFMRI. A graphical method for at‐a‐glance assessment of reliability and repeatability, effect sizes, and outlier identification in multisite‐multisession neuroimaging studies is introduced.Level of Evidence: 1Technical Efficacy: Stage 2J. Magn. Reson. Imaging 2019;50:878–888.Keywords
Funding Information
- National Institutes of Health (S10 OD016356, S10 OD018224, S10 RR0276694)
- Race to Erase MS Foundation
This publication has 34 references indexed in Scilit:
- Quantitative magnetic resonance imaging phantoms: A review and the need for a system phantomMagnetic Resonance in Medicine, 2017
- Advanced MRI unravels the nature of tissue alterations in early multiple sclerosisAnnals of Clinical and Translational Neurology, 2014
- On the accuracy of T1 mapping: Searching for common groundMagnetic Resonance in Medicine, 2014
- Imaging of repeated episodes of demyelination and remyelination in multiple sclerosisNeuroImage: Clinical, 2014
- Improving diffusion MRI using simultaneous multi-slice echo planar imagingNeuroImage, 2012
- Diffusion imaging in multiple sclerosis: research and clinical implicationsNMR in Biomedicine, 2010
- A topology-preserving approach to the segmentation of brain images with multiple sclerosis lesionsNeuroImage, 2010
- Measuring fMRI reliability with the intra-class correlation coefficientNeuroImage, 2009
- Reliability of MRI-derived cortical and subcortical morphometric measures: Effects of pulse sequence, voxel geometry, and parallel imagingNeuroImage, 2009
- Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivoMagnetic Resonance in Medicine, 2007