Monocular Vision- and IMU-Based System for Prosthesis Pose Estimation During Total Hip Replacement Surgery
Authors:
- 19 May 2017
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 11 (3) , 661-670
Abstract
The average age of population increases worldwide, so does the number of total hip replacement surgeries. Total hip replacement, however, often involves a risk of dislocation and prosthetic impingement. To minimize the risk after surgery, we propose an instrumented hip prosthesis that estimates the relative pose between prostheses intraoperatively and ensures the placement of prostheses within a safe zone. We create a model of the hip prosthesis as a ball and socket joint, which has four degrees of freedom (DOFs), including 3-DOF rotation and 1-DOF translation. We mount a camera and an inertial measurement unit (IMU) inside the hollow ball, or “femoral head prosthesis,” while printing customized patterns on the internal surface of the socket, or “acetabular cup.” Since the sensors were rigidly fixed to the femoral head prosthesis, measuring its motions poses a sensor ego-motion estimation problem. By matching feature points in images of the reference patterns, we propose a monocular vision based method with a relative error of less than 7% in the 3-DOF rotation and 8% in the 1-DOF translation. Further, to reduce system power consumption, we apply the IMU with its data fused by an extended Kalman filter to replace the camera in the 3-DOF rotation estimation, which yields a less than 4.8% relative error and a 21.6% decrease in power consumption. Experimental results show that the best approach to prosthesis pose estimation is a combination of monocular vision-based translation estimation and IMU-based rotation estimation, and we have verified the feasibility and validity of this system in prosthesis pose estimation.Keywords
Funding Information
- National Natural Science Foundation of China (61674090)
- National High Technology Research and Development Program of China (863 Program) (2015AA016601)
- Beijing Engineering Research Center (BG0149)
This publication has 36 references indexed in Scilit:
- High-Tech Hip Implant for Wireless Temperature Measurements In VivoPLOS ONE, 2012
- Bony Impingement Limits Design-related Increases in Hip Range of MotionClinical Orthopaedics and Related Research, 2012
- Total hip joint prosthesis for in vivo measurement of forces and momentsMedical Engineering & Physics, 2009
- Functional calibration procedure for 3D knee joint angle description using inertial sensorsJournal of Biomechanics, 2009
- Dislocation Following Total Hip Replacement: The Avon Orthopaedic Centre ExperienceThe Annals of The Royal College of Surgeons of England, 2008
- Bony impingement affects range of motion after total hip arthroplasty: A subject‐specific approachJournal of Orthopaedic Research, 2008
- Anatomic Hip Range of Motion After Implantation During Total Hip Arthroplasty as Measured by a Navigation SystemThe Journal of Arthroplasty, 2007
- Projections of Primary and Revision Hip and Knee Arthroplasty in the United States from 2005 to 2030Journal of Bone and Joint Surgery, 2007
- Is there really a “safe zone” for the placement of total hip components?2006
- CT-basierte und CT-freie Navigation in der Knieendoprothetik - eine prospektive Vergleichsstudie unter klinischem und radiologischem AspektZeitschrift für Orthopädie und ihre Grenzgebiete, 2005