Optimization of the Probe Coverage in DNA Biosensors by a One‐Step Coadsorption Procedure
- 10 December 2013
- journal article
- research article
- Published by Wiley in ChemElectroChem
- Vol. 1 (1) , 147-157
Abstract
Analytical performance (selectivity, sensitivity, limit of detection) of a sensor is ultimately connected to the interfacial architecture of the sensing surface that needs to be optimized. Self‐assembly of a mixed monolayer of thiolated probes and diluent onto gold surfaces used in the design of biosensing platforms is nowadays commonly performed by a two‐step immobilization procedure. In this work, the merits of a one‐step coadsorption procedure are emphasized, and it is shown that the ionic strength is a very efficient tool to fine control the surface concentration of the immobilized probe. Probe densities were obtained by alternating current voltammetry or fluorescence measurements depending on the type of labeling of the probes. With unlabeled DNA sequences, chronocoulometric measurements were performed in the presence of dissolved hexaammineruthenium(III) cations. The maximum probe density achievable at high ionic strength by the one‐step coadsorption procedure is limited by steric constraints and depends on the structure of the sequence. Various thiolated DNA sequences (single‐stranded DNA, double‐stranded DNA, linear, hairpin, quadruplex) coadsorbed with a common diluent, 4‐mercaptobutan‐1‐ol, were used to discuss the structural factors affecting the maximum surface densities obtained for the different types of probe. Application of the one‐step coadsorption procedure to the optimization of the analytical performance of a protein aptasensor is illustrated by building a sensor for the detection of thrombin on the basis of the thrombin binding aptamer sequence.Keywords
This publication has 76 references indexed in Scilit:
- Electric-Field Dependent Conformations of Single DNA Molecules on a Model Biosensor SurfaceNano Letters, 2012
- High-resolution structures of two complexes between thrombin and thrombin-binding aptamer shed light on the role of cations in the aptamer inhibitory activityNucleic Acids Research, 2012
- Ternary monolayers as DNA recognition interfaces for direct and sensitive electrochemical detection in untreated clinical samplesBiosensors and Bioelectronics, 2011
- Hybridization Efficiency of Molecular Beacons Bound to Gold Nanowires: Effect of Surface Coverage and Target LengthLangmuir, 2010
- Folding-Based Electrochemical Biosensors: The Case for Responsive Nucleic Acid ArchitecturesAccounts of Chemical Research, 2010
- Optimization of Electrochemical Aptamer-Based Sensors via Optimization of Probe Packing Density and Surface ChemistryLangmuir, 2008
- Molecular Beacon−Metal Nanowire Interface: Effect of Probe Sequence and Surface Coverage on Sensor PerformanceLangmuir, 2008
- DNA surface hybridization regimesProceedings of the National Academy of Sciences of the United States of America, 2008
- Effect of Molecular Crowding on the Response of an Electrochemical DNA SensorLangmuir, 2007
- VMD: Visual molecular dynamicsJournal of Molecular Graphics, 1996