The Systolic Index: A Noninvasive Approach for the Assessment of Cardiac Function: Implications for Patients with DDD and CRT Devices
- 13 June 2013
- journal article
- clinical trial
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 36 (10) , 1284-1293
Abstract
Background Our objective was to evaluate the systolic index (SI), the ratio between rate‐corrected left ventricular ejection time (LVETc), and a preejection period surrogate (PEPsu), to assess cardiac function in patients with DDD and cardiac resynchronization therapy (CRT) pacemakers. Methods LVETc and PEPsu were automatically measured from electrocardiogram and finger photoplethismography. Atrioventricular (AV) and mode switch (CRT to DDD) were used as hemodynamic challenges. Performance of SI, beat‐by‐beat systolic blood pressure (SBP), and Doppler aortic velocity/time integral (AoVTI) were compared in 36 patients, and SI's detection of CRT to DDD mode switch in nine patients, responders to CRT. AVs were changed from 30 ms to 250 ms (20 ms steps) at constant paced heart rate, alternating with a reference AV (RefAV), to reduce hemodynamic drift. The coefficient of variation (standard deviation/mean) of SI, SBP, and AoVTI during all RefAVs were used as error marker. The percentage detection of hemodynamic changes during AV transitions was a marker of sensitivity. Results Fifty‐five patients (males 62%, age 69.6 ± 17) were studied. SI detected 441 of 544 transitions (81%) versus 361 (66%) of SBP (P = 0.005). Error during RefAVs was smaller for SI (3.4%) as compared to AoVTI (7.8%, P = 0.015) and to SBP (5.7%, P = 0.005). SIs correlated with AoVTI (R from 0.71 to 0.98, all P < 0.001). SI detected all CRT to DDD changes (P < 0.001). Conclusion The noninvasive SI obtained with a simple, observer‐independent hemodynamic assessment procedure has higher accuracy than SBP and AoVTI and better sensitivity than SBP. It detects mechanical resynchronization in CRT and allows programming a suitable AV delay.Keywords
This publication has 29 references indexed in Scilit:
- Extraordinarily Favorable Left Ventricular Reverse Remodeling through Long‐Term Cardiac Resynchronization: Super‐Response to Cardiac ResynchronizationPacing and Clinical Electrophysiology, 2012
- Comparison of myocardial performance index versus ratio of isovolumic contraction time/ejection time in left ventricular systolic dysfunctionAdvances in Therapy, 2007
- Cardiac resynchronization therapy optimization by finger plethysmographyHeart Rhythm, 2004
- Proposal of a Method for Automatic Optimization of Left Heart Atrioventricular Interval Applicable to DDD PacemakersPacing and Clinical Electrophysiology, 1995
- Nonphysiological Left Heart AV Intervals as a Result of DDD and AAI “Physiological” PacingPacing and Clinical Electrophysiology, 1991
- The isovolumic index: A new noninvasive approach to the assessment of left ventricular function in manThe American Journal of Cardiology, 1982
- Left Ventricular Ejection Time by Densitometry in Patients at Rest and During Exercise, Atrial Pacing and Atrial FibrillationCirculation, 1974
- Ejection Time by Ear Densitogram and Its DerivativeCirculation, 1973
- Densitography: A new method for evaluation of cardiac performance at rest and during exerciseAmerican Heart Journal, 1972
- Systolic Time Intervals in Heart Failure in ManCirculation, 1968