Are Distal Femoral Traction Pins Intra-Articular? A Cadaveric Study
Authors:
- Brion BenningerBBBrion Benninger
- Sawyer SmithSSSawyer Smith
- Amer MirzaAMAmer Mirza
- Lynn MarshallLMLynn Marshall
- Darin FriessDFDarin Friess
- 1 November 2013
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 27 (11) , e250-e253
Abstract
To examine the frequency of intra-articular placement of distal femoral traction pins and their proximity to the superficial femoral artery (SFA). Wires were placed in the distal femurs of 28 cadaveric knees at the adductor tubercle (ADT), the superior pole of the patella (SPP), and 2 cm proximal to SPP (SPP+2). A lateral fluoroscopic image was obtained after injection of radiopaque contrast to assess for joint penetration. Dissection was performed to confirm or refute fluoroscopic findings. The distance from each wire to the SFA was measured. The percentage of intra-articular placement was higher (29%) at the ADT than the SPP+2 (0%) level. The mean (SD) distances from the ADT, SPP, and SPP+2 to the SFA were 7.4 (±1.8) cm, 5.7 (±1.7) cm, and 3.8 (±1.7) cm, respectively (P < 0.0001). None of the wires penetrated the femoral artery. The proportion of wires judged to be intra-articular was not statistically different whether judged by fluoroscopy or anatomic dissection (exact P = 1.0). Wires placed at the level of the ADT are at risk for capsular penetration. Risk of major vascular injury with transmedullary placement at all levels seems to be minimal. The optimum position for distal femoral pins remains unknown, but aiming >0.7 cm proximal to the ADT may lower the risk of intra-articular placement. No difference was detected between fluoroscopic arthrography and gross dissection.Keywords
This publication has 9 references indexed in Scilit:
- Lateral femoral traction pin entry: risk to the femoral artery and other medial neurovascular structuresJournal of Orthopaedic Surgery and Research, 2010
- Heterotopic Ossification of the Quadriceps Following Distal Femoral TractionJournal of Orthopaedic Trauma, 2004
- Safe Placement of Proximal Tibial Transfixation Wires With Respect to Intracapsular PenetrationJournal of Orthopaedic Trauma, 2001
- Anatomy of the Distal Knee Joint and Pyarthrosis Following External FixationJournal of Orthopaedic Trauma, 1999
- Safe Extracapsular Placement of Proximal Tibia Transfixation PinsJournal of Orthopaedic Trauma, 1999
- Infections in Periarticular Fractures of the Lower Extremity Treated with Tensioned Wire Hybrid FixatorsJournal of Orthopaedic Trauma, 1998
- External fixation and limited internal fixation for complex fractures of the tibial plateau.Journal of Bone and Joint Surgery, 1995
- Anatomy of the Medial Distal Femur: A Study of the Adductor HiatusJournal of Orthopaedic Trauma, 1995
- Rupture of the knee capsule from articular hyperpressure: Experiments in cadaver kneesActa Orthopaedica, 1988