Anatomic stemless shoulder arthroplasty and related outcomes: a systematic review
Open Access
- 30 August 2016
- journal article
- review article
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 17 (1) , 376
Abstract
The latest generation of shoulder arthroplasty includes canal-sparing respectively stemless designs that have been developed to allow restoration of the glenohumeral center of rotation independently from the shaft, and to avoid stem-related complications. The stemless prosthesis design has also recently been introduced for use in reverse arthroplasty systems. We systematically reviewed the literature for studies of currently available canal-sparing respectively stemless shoulder arthroplasty systems. From the identified series, we recorded the indications, outcome measures, and humeral-sided complications. We identified 11 studies of canal-sparing respectively stemless anatomic shoulder arthroplasty implants, published between 2010 and 2016. These studies included 929 cases, and had a mean follow-up of 26 months (range, 6 to 72 months). The rates of humeral component-related complications ranged between 0 and 7.9 %. The studies reported only a few isolated cases of complications of the humeral component. Some arthroplasty systems are associated with radiological changes, but without any clinical relevance. All of the published studies of canal-sparing respectively stemless shoulder arthroplasty reported promising clinical and radiological outcomes in short to midterm follow-up. Long-term studies are needed to demonstrate the long-term value of these kind of implants.Keywords
This publication has 33 references indexed in Scilit:
- Impact of prosthetic design on clinical and radiologic outcomes of total shoulder arthroplasty: a prospective studyJournal of Shoulder and Elbow Surgery, 2013
- Stemless shoulder prosthesis versus conventional anatomic shoulder prosthesis in patients with osteoarthritisJournal of Orthopaedics and Traumatology, 2012
- Factors predicting complication rates after primary shoulder arthroplastyJournal of Shoulder and Elbow Surgery, 2011
- Results of a new stemless shoulder prosthesis: Radiologic proof of maintained fixation and stability after a minimum of three years' follow-upJournal of Shoulder and Elbow Surgery, 2010
- Copeland surface replacement of the shoulderThe Journal of Bone and Joint Surgery. British volume, 2007
- Complications of total shoulder arthroplasty: Are they fewer or different?Journal of Shoulder and Elbow Surgery, 2006
- Total shoulder arthroplasty: Long-term survivorship, functional outcome, and quality of lifeJournal of Shoulder and Elbow Surgery, 2005
- Minimum fifteen-year follow-up of Neer hemiarthroplasty and total shoulder arthroplasty in patients aged fifty years or youngerJournal of Shoulder and Elbow Surgery, 2004
- Cementless surface replacement arthroplasty (Copeland CSRA) for osteoarthritis of the shoulderJournal of Shoulder and Elbow Surgery, 2004
- Cementless surface replacement arthroplasty of the shoulderThe Journal of Bone and Joint Surgery. British volume, 2001