Fluence smoothing evaluation for whole‐breast automatically generated treatment plans
Open Access
- 29 November 2024
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (2) , e14564
Abstract
Purpose: This study aimed to identify the fluence smoothing threshold that preserves the dosimetric quality of planning for breast cancer intensity‐modulated radiation therapy (IMRT).Material and methods: We conducted automated treatment planning for 60 breast cancer patients using the Eclipse Scripting Application Programming Interface. The plans included four‐field IMRT, emphasizing smoothing weight combinations while maintaining a 4:3 aspect ratio between the X and Y directions. Four weight sets (40 × 30, 100 × 75, 150 × 115.2, and 200 × 150) were tested, resulting in four plans per patient. A total dose of 40.05 Gy over 15 fractions was prescribed. Optimization weigths were dynamically adjusted based on dosimetric evaluations, with the maximum coverage priority set at 200. Statistical analyses were used to assess the dosimetric data.Results: The median planning target volume (PTV) coverage varied across smoothing levels, with default smoothing (40 × 30) providing superior median PTV coverage. Lung constraints showed significant differences mainly at higher smoothing levels. Heart constraints exhibited less variation between smoothing levels, with significant differences primarily in the maximum and mean doses for right‐sided patients and between default and higher smoothing levels for left‐sided patients. No significant differences were observed in contralateral breast constraints among all smoothing levels, except at the maximum level for right‐sided patients. Monitor units decreased with increasing smoothing weight, showing significant differences between default and other settings. For right‐sided patients, the median number of monitor units varied from 1346 (40 × 30) to 754 (200 × 150), and for left‐sided patients, from 1333 (40 × 30) to 804 (200 × 150). Chi‐square tests revealed differences in dose constraint adherence between default and maximum smoothing levels, particularly in target coverage.Conclusion: Our findings suggest that using a ratio of smoothing weights to target priorities between 1:1.5 and 1:1.6 leads to a favorable balance between complexity and dosimetric plan quality, with no significant impacts on dose constraint adherence.Keywords
This publication has 28 references indexed in Scilit:
- Automated treatment planning for whole breast irradiation with individualized tangential IMRT fieldsJournal of Applied Clinical Medical Physics, 2024
- Technical Report: Efficient constancy evaluation of the Eclipse treatment planning system's photon and electron dose calculation algorithms aided by the third-party ClearCheck softwareMedical Dosimetry, 2023
- Dosimetric and Radiobiological Impact of Flattening Filter‐Free Beam and Dose Calculation Algorithm Using RapidArc Plans for Cervical Cancer TreatmentPrecision Radiation Oncology, 2023
- Complexity in Radiation Therapy: It's ComplicatedInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2020
- Comparison of complexity metrics for multi-institutional evaluations of treatment plans in radiotherapyPhysics and Imaging in Radiation Oncology, 2018
- Volumetric‐modulated arc therapy and intensity‐modulated radiation therapy treatment planning for prostate cancer with flattened beam and flattening filter free linear acceleratorsJournal of Applied Clinical Medical Physics, 2017
- Effects of Setup Errors and Shape Changes on Breast RadiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- The Tradeoff Between Treatment Plan Quality and Required Number of Monitor Units in Intensity-modulated RadiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Intensity-modulated radiation therapy, protons, and the risk of second cancersInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- IMRT treatment planning—A comparative inter-system and inter-centre planning exercise of the ESTRO QUASIMODO groupRadiotherapy and Oncology, 2005