Transradial Approach to Coil Embolization of an Intracranial Aneurysm
- 1 August 2004
- journal article
- case report
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 11 (4) , 411-413
Abstract
Purpose: To report the use of a transradial approach to coil embolization of an intracranial aneurysm in a morbidly obese patient. Technical Note: When the transfemoral approach was inaccessible in a morbidly obese patient with a ruptured intracranial aneurysm, coil embolization was performed via a 6-F sheath placed in the radial artery. Multiple platinum coils were delivered to exclude the 14-mm basilar tip aneurysm. Because heparin was not reversed, the sheath was left in the artery for 24 hours then removed. The radial artery was pulsatile, and blood supply to the hand was good. Conclusions: The radial artery appears to be a suitable route for access to the intracranial vessels when the femoral artery is not available.Keywords
This publication has 8 references indexed in Scilit:
- Transradial Cerebral Angiography: An Alternative RouteNeurosurgery, 2002
- Brachial, radial, or femoral approach for elective Palmaz-Schatz stent implantation: A randomized comparisonCatheterization and Cardiovascular Diagnosis, 1997
- A Randomized Comparison of Percutaneous Transluminal Coronary Angioplasty by the Radial, Brachial and Femoral Approaches: The Access StudyJACC, 1997
- Frequency of a positive modified Allen's test in 1,000 consecutive patients undergoing cardiac catheterizationCatheterization and Cardiovascular Diagnosis, 1996
- Transradial approach for coronary angiography and angioplastyThe American Journal of Cardiology, 1995
- Transradial artery coronary angioplastyAmerican Heart Journal, 1995
- Percutaneous transradial artery approach for coronary Palmaz-Schatz stent implantationAmerican Heart Journal, 1994
- Percutaneous radial artery approach for coronary angiographyCatheterization and Cardiovascular Diagnosis, 1989