Abstract
Aims The rising number of cardiovascular implantable electronic devices has led to a steep increase in transvenous lead extractions (TLEs). Procedure-related, haemodynamically significant adverse events are uncommon during TLE yet remain an inevitable risk. While the use of transoesophageal echocardiography (TEE) as a guide to clinical decision-making during refractory circulatory instability has been well established, the specific utility of rescue TEE during TLE has not been comprehensively studied. Methods and results Twenty-six patients who required emergent TEE to determine the aetiology of intractable haemodynamic instability during TLE were evaluated. Pericardial effusion requiring urgent pericardiocentesis and/or cardiac surgical intervention was diagnosed by TEE in 10 patients, and progressed to cardiac arrest in 4 patients. Haemorrhagic shock developed in two patients suffering from femoral vein laceration and right haemothorax, respectively. One additional patient developed acute respiratory compromise and right ventricular dysfunction diagnosed by TEE, which necessitated prolonged post-operative intubation and inotropic therapy. In 14 patients, TEE excluded life-threatening cardiovascular injuries and enabled the pursuit of continued medical management. Two patients with reassuring TEE findings underwent intra-operative placement of chest tubes for pneumothorax. All the 26 patients were discharged from the hospital. Conclusion While TLE is a relatively safe procedure, life-threatening cardiovascular injuries remain a rare risk. In this study, the use of rescue TEE ruled out significant cardiovascular injuries in the majority of patients. Furthermore, rescue TEE had a substantial impact on the efficiency of determining the aetiology of refractory haemodynamic instability during TLE and thereby facilitated the timely initiation of definitive intervention.Keywords
This publication has 26 references indexed in Scilit:
- Relationship between Intraoperative Mean Arterial Pressure and Clinical Outcomes after Noncardiac SurgeryAnesthesiology, 2013
- The challenges of transvenous lead extractionHeart, 2011
- Practice Guidelines for Perioperative Transesophageal EchocardiographyAnesthesiology, 2010
- Clinical Utility of Intraprocedural Transesophageal Echocardiography during Transvenous Lead ExtractionJournal of the American Society of Echocardiography, 2008
- The Usefulness of Transesophageal Echocardiography During Intraoperative Cardiac Arrest in Noncardiac SurgeryAnesthesia & Analgesia, 2006
- Decrease in fluoroscopic cardiac silhouette excursion precedes hemodynamic compromise in intraprocedural tamponadeHeart Rhythm, 2005
- Biplane transoesophageal echocardiographic detection of myocardial ischaemia in patients with coronary artery disease undergoing non-cardiac surgery: segmental wall motion vs. electrocardiography and haemodynamic performanceEuropean Journal of Anaesthesiology, 1997
- Prediction of Intraoperative Hypovolemia in Patients with Left Ventricular Hypertrophy: Comparison of Transesophageal Echocardiography and Swan‐Ganz MonitoringEchocardiography, 1997
- Echocardiographic and Hemodynamic Indexes of Left Ventricular Preload in Patients with Normal and Abnormal Ventricular FunctionAnesthesiology, 1994
- Prolongation of Postoperative Sufentanil Analgesia with EpinephrineAnesthesiology, 1988