In vitro evaluation of delamination resistance of PEEK and CFR-PEEK
Authors:
- 25 August 2021
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 236 (2) , 279-285
Abstract
Poly-ether-ether-ketone (PEEK) and carbon fiber reinforced PEEK as orthopedic implant materials exhibit excellent material properties. Although delamination of PEEK materials has been reported in knee joint wear research, the delamination resistance behavior remains unclear. In this study, the delamination resistance of PEEK materials was investigated; these materials were compared to ultra-high molecular weight polyethylene (UHMWPE). The results of a ball-on-flat type delamination test indicated that the PEEK materials underwent delamination considerably earlier than UHMWPE, and the contact area of the PEEK materials was smaller than that of UHMWPE. Moreover, the indentation modulus, hardness, and coefficient of friction were higher for PEEK materials than for UHMWPE. The reduced tendency of PEEK materials to undergo deformation to mitigate stress concentration at low conformity contact conditions contributed to their inferior delamination resistance compared to that of UHMWPE. The delamination resistance of the PEEK materials was equivalent to that of degraded UHMWPE, which highlights the risk of delamination of PEEK implants in a clinical context. Consequently, when using PEEK materials as an implant component loaded at a low conformity contact condition, the material selection and component design must be carefully considered. Overall, the results of this study can help guide the future development of PEEK-based implants.Keywords
Funding Information
- Japan Agency for Medical Research and Development (JP20mk0102116)
This publication has 25 references indexed in Scilit:
- Polyetheretherketone (PEEK) for medical applicationsJournal of Materials Science: Materials in Medicine, 2016
- Improved Resistance to Neck-Liner Impingement in Second-Generation Highly Crosslinked Polyethylene—The Role of Vitamin E and CrosslinksThe Journal of Arthroplasty, 2016
- The Influence of Sterilization Method on Articular Surface Damage of Retrieved Cruciate-Retaining Tibial InsertsThe Journal of Arthroplasty, 2012
- Wear of ceramic‐on‐carbon fiber‐reinforced poly‐ether ether ketone hip replacementsJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2012
- In Vivo Oxidation Contributes to Delamination but not Pitting in Polyethylene Components for Total Knee ArthroplastyThe Journal of Arthroplasty, 2011
- Gamma Inert Sterilization: A Solution to Polyethylene Oxidation?Journal of Bone and Joint Surgery, 2009
- Patient and surgery related factors associated with fatigue type polyethylene wear on 49 PCA and DURACON retrievals at autopsy and revisionJournal of Orthopaedic Surgery and Research, 2008
- PEEK biomaterials in trauma, orthopedic, and spinal implantsBiomaterials, 2007
- Wear Resistance and Mechanical Properties of Highly Cross-linked, Ultrahigh–Molecular Weight Polyethylene Doped With Vitamin EThe Journal of Arthroplasty, 2006
- Suitability and limitations of carbon fiber reinforced PEEK composites as bearing surfaces for total joint replacementsWear, 1999