A new practical technique to reduce allogeneic blood exposure and hospital costs while preserving clotting factors after cardiopulmonary bypass: the Hemobag®
Authors:
- 1 December 2005
- journal article
- research article
- Published by SAGE Publications in Perfusion
- Vol. 20 (6) , 343-349
Abstract
Recent data independently linking allogeneic blood use to increased morbidity and mortality after cardiopulmonary bypass (CPB) warrants the study of new methods to employ unique and familiar technology to reduce allogeneic blood exposure. The Hemobag® allows the open-heart team to concentrate residual CPB circuit contents and return a high volume of autologous clotting factors and blood cells to the patient. Fifty patients from all candidates were arbitrarily selected to receive the Hemobag® (HB) therapy. A retrospective control group of 50 non-Hemobag® (NHB) patients were matched to the HB group patient-by-patient for comparison according to surgeon, type of procedure, age, body surface area (BSA), body weight and CPB time. Many efforts to conserve blood (Cell Saver® and ANH) were employed in both groups. Post-CPB cell washing of circuit contents was additionally employed in the control group. There were no significant differences between the HB and NHB groups in regard to patient morphology, pre-op cell concentrations, distribution of surgeon or procedures (41% valve, 16% valve/coronary artery bypass graft (CABG), balance CABG), pump and ischemic times and Bayes National Risk scores. The average volume returned to the patient from the HB was 8179/198 mL (1 SD). Average processing time was 11 min. The Hemobag®contained an average platelet count of 2309/80 K/mm3, fibrinogen concentration of 4139/171 mg/dl, total protein of 8.09/2.8 gm/dl, albumin of 4.49/1.2 gm/dl and hematocrit of 439/7%. Factor VII, IX and X levels in three HB contents averaged 259% greater than baseline. Substantial reductions were achieved in both allogeneic blood product avoidance and cost to the hospital with use of the HB. Infusion of the Hemobag® concentrate appears to recover safely substantial proteins, clotting factor and cell concentration for all types of cardiac procedures, maintaining the security of a primed circuit.Keywords
This publication has 19 references indexed in Scilit:
- Hypothermia-induced platelet aggregation and cognitive decline in coronary artery bypass surgery: a pilot studyPerfusion, 2005
- Hemodilution during cardiopulmonary bypass is an independent risk factor for acute renal failure in adult cardiac surgeryThe Journal of Thoracic and Cardiovascular Surgery, 2005
- ?Off-license? use of recombinant activated factor VIIBlood Reviews, 2004
- An Ultrafiltration Technique for Directly Reinfusing Residual Cardiopulmonary Bypass BloodThe Journal of ExtraCorporeal Technology, 2004
- Abstracts of Posters Presented at the International Anesthesia Research Society 78th Clinical and Scientific Congress Tampa, FL March 27-31, 2004Anesthesia & Analgesia, 2004
- Cell Saver, Ultrafiltration and Direct Transfusion: Comparative Study of Three Blood Processing TechniquesThe Thoracic and Cardiovascular Surgeon, 2001
- Lowest hematocrit on bypass and adverse outcomes associated with coronary artery bypass graftingThe Annals of Thoracic Surgery, 2001
- Retrograde Autologous Priming For Cardiopulmonary Bypass: A Safe And Effective Means Of Decreasing Hemodilution And Transfusion RequirementsThe Journal of Thoracic and Cardiovascular Surgery, 1998
- Comparison of three blood-processing techniques during and after cardiopulmonary bypassThe Annals of Thoracic Surgery, 1993
- Blood Conservation Techniques and Platelet Function in Cardiac SurgeryAnesthesiology, 1991