N‐Nitrosamines (NAms) are suspected human carcinogens that have been identified as drinking water and wastewater pollutants. In this work, a sensitive screening/confirmation method was proposed for the determination of the most toxic NAms that can be found in water samples (N‐nitrosodimethylamine, N‐nitrosodiethylamine, N‐nitrosodibutylamine, N‐nitrosomorpholine, N‐nitrosopiperidine, and N‐nitrosopyrrolidine). A sample volume of 250 mL was first preconcentrated in an automatic SPE unit and then the extract was concentrated to a final volume of 10 μL (providing a preconcentration factor of 25 000). Aliquots of the extract were subjected to a rapid screening process (1.6 min) by using a short capillary polar column (1.5 m length) and GC with nitrogen–phosphorous detection. In this way, the high number of samples to be tested routinely in a water laboratory is simplified due to a reduction in the analysis time. Thus, the screening method acts as a filter that indicates whether target analytes are present, above or below the cut‐off level (3.8 or 10.4 ng/L), giving no false negatives at concentrations below the guide values for NAms in drinking water established by different countries. Positive samples (tap and swimming pool waters) were then confirmed by GC‐MS detection.Keywords
Funding Information
- Spanish Ministry of Education (CTQ2007-63962/BQU)
- Junta of Andalucian (PO7-FQM-02493)
This publication has 18 references indexed in Scilit:
- A nationwide survey of NDMA in raw and drinking water in JapanScience of The Total Environment, 2009
- Fast gas chromatography for pesticide residues analysisJournal of Chromatography A, 2008
- Analysis of nitrosamines in water by automated SPE and isotope dilution GC/HRMSOccurrence in the different steps of a drinking water treatment plant, and in chlorinated samples from a reservoir and a sewage treatment plant effluentTalanta, 2008
- Analysis of Nitrosamines in Wastewater: Exploring the Trace Level Quantification Capabilities of a Hybrid Linear Ion Trap/Orbitrap Mass SpectrometerAnalytical Chemistry, 2008
- Automatic screening method for the preconcentration and determination of N-nitrosamines in waterTalanta, 2007
- Comparison of the sensitivities of seven N-nitrosamines in pre-screened waters using an automated preconcentration system and gas chromatography with different detectorsJournal of Chromatography A, 2007
- Analysis of disinfection by-products in drinking water by LC–MS and related MS techniquesTrAC Trends in Analytical Chemistry, 2005
- Continuous flow systems for rapid sample screeningTrAC Trends in Analytical Chemistry, 2002
- Qualitative Analysis RevisitedCritical Reviews in Analytical Chemistry, 2000
- Determination of N-Nitrosodimethylamine at Part-per-Trillion Levels in Drinking Waters and Contaminated GroundwatersAnalytical Chemistry, 1995