New Method of Parent Catheter Advancement in the Balloon Anchor Technique during Balloon-Occluded Transarterial Chemoembolization for Hepatic Tumors
Authors:
Open Access
- 31 May 2016
- journal article
- case report
- Published by Hindawi Limited in Case Reports in Radiology
- Vol. 2016, 1-4
Abstract
Balloon-occluded transarterial chemoembolization (B-TACE) using a microballoon catheter is a promising method for improvement of lipiodol emulsion accumulation and local control relative to conventional transarterial chemoembolization. This method has been referred to as the balloon anchor technique in previous reports. We report a new technique for successful parent catheter advancement for achievement of stable backup for the selective insertion of a microballoon catheter during B-TACE using the microballoon as an anchor, even in patients with tortuous anatomy of the hepatic and celiac arteries. Deep cannulation of parent catheters was accomplished in all three cases and complications such as vascular injury were not observed in the postprocedure angiograms.Keywords
This publication has 8 references indexed in Scilit:
- Balloon-occluded transarterial chemoembolization using a 1.8-French tip Coaxial microballoon catheter for hepatocellular carcinoma: Technical and safety considerationsMinimally Invasive Therapy & Allied Technologies, 2014
- Safety and efficacy of balloon‐occluded transcatheter arterial chemoembolization using miriplatin for hepatocellular carcinomaHepatology Research, 2014
- Predictive Factor of Local Recurrence after Balloon-Occluded TACE with Miriplatin (MPT) in Hepatocellular CarcinomaPLOS ONE, 2014
- Dense Accumulation of Lipiodol Emulsion in Hepatocellular Carcinoma Nodule during Selective Balloon-occluded Transarterial Chemoembolization: Measurement of Balloon-occluded Arterial Stump PressureCardioVascular and Interventional Radiology, 2012
- The balloon anchor technique: a novel technique for distal access through a giant aneurysmJournal of NeuroInterventional Surgery, 2010
- Large dilating balloon to allow endoscope insertion for successful endoscopic retrograde cholangiopancreatography in patients with surgically altered anatomy (with video)Journal of Hepato-Biliary-Pancreatic Sciences, 2010
- Anchor balloon technique for very tortuous lesions by transradial coronary intervention.2008
- New technique for superior guiding catheter support during advancement of a balloon in coronary angioplasty: The anchor techniqueCatheterization and Cardiovascular Interventions, 2003