Efficacy of the slow firing method using a reinforced triple-row stapler for preventing postoperative pancreatic fistula during laparoscopic distal pancreatectomy
Authors:
- 28 July 2021
- journal article
- research article
- Published by Springer Nature in Surgery Today
- Vol. 52 (2) , 260-267
Abstract
Purpose Postoperative pancreatic fistula (POPF) remains the most clinically relevant complication of laparoscopic distal pancreatectomy (LDP). The present study evaluated the efficacy of the “slow firing method” using a reinforced triple-row stapler (Covidien, Tokyo, Japan) during LDP. Methods This retrospective single-center study included 73 consecutive patients who underwent LDP using the slow firing method. A black cartridge was used in all patients. The primary endpoint was the rate of clinically relevant POPF (CR-POPF) after LDP. Secondary endpoints included perioperative outcomes and factors associated with CR-POPF as well as the correlation between the transection time and thickness of the pancreas. Results Four patients (5.5%) developed CR-POPF (grade B). Overall morbidity rates, defined as grade ≥ II and ≥ III according to the Clavien-Dindo classification, were 21 and 11%, respectively. The median postoperative hospital stay was 10 days. Preoperative diabetes (13.6 vs. 0.2%, P = 0.044) and thickness of the pancreas ≥ 15 mm (13.8% vs. 0%, P = 0.006) were identified as independent risk factors for CR-POPF. The median transection time was 16 (8–29) min. Conclusion The slow firing method using a reinforced triple-row stapler for pancreatic transection is simple, safe, and effective for preventing CR-POPF after LDP.Keywords
This publication has 33 references indexed in Scilit:
- Minimally invasive RAMPS in well-selected left-sided pancreatic cancer within Yonsei criteria: long-term (>median 3 years) oncologic outcomesSurgical Endoscopy, 2014
- Efficacy of an Absorbable Fibrin Sealant Patch (TachoSil) After Distal PancreatectomyAnnals of Surgery, 2012
- Pancreatic thickness as a predictive factor for postoperative pancreatic fistula after distal pancreatectomy using an endopath staplerSurgery Today, 2012
- Mesh Reinforcement of Pancreatic Transection Decreases Incidence of Pancreatic Occlusion Failure for Left PancreatectomyAnnals of Surgery, 2012
- The Effect of Prophylactic Transpapillary Pancreatic Stent Insertion on Clinically Significant Leak Rate Following Distal PancreatectomyAnnals of Surgery, 2012
- Efficacy of stapler versus hand-sewn closure after distal pancreatectomy (DISPACT): a randomised, controlled multicentre trialThe Lancet, 2011
- Prolonged peri-firing compression with a linear stapler prevents pancreatic fistula in laparoscopic distal pancreatectomySurgical Endoscopy, 2010
- Randomized clinical trial of techniques for closure of the pancreatic remnant following distal pancreatectomyBritish Journal of Surgery, 2009
- Classification of Surgical ComplicationsAnnals of Surgery, 2004
- Temporary Fibrin Glue Occlusion of the Main Pancreatic Duct in the Prevention of Intra-Abdominal Complications After Pancreatic ResectionAnnals of Surgery, 2003