A Comparative Study on the Suitability of Smartphones and IMU for Mobile, Unsupervised Energy Expenditure Calculi
Open Access
Abstract
The metabolic equivalent of task (MET) is currently the most used indicator for measuring the energy expenditure (EE) of a physical activity (PA) and has become an important measure for determining and supervising a person’s state of health. The use of new devices which are capable of measuring inertial movements by means of built-in accelerometers enable the PA to be measured objectively on the basis of the reckoning of “counts”. These devices are also known as inertial measurement units (IMUs) and each count is an aggregated value indicating the intensity of a movement and can be used in conjunction with other parameters to determine the MET rate of a particular physical activity and thus it’s associated EE. Various types of inertial devices currently exist that enable count calculus and physical activity to be monitored. The advent of mobile devices, such as smartphones, with empowered computation capabilities and integrated inertial sensors, has enabled EE to be measure in a distributed, ubiquitous and natural way, thereby overcoming the reluctance of users and practitioners associated with in-lab studies. From the point of view of the process analysis and infrastructure needed to manage data from inertial devices, there are also various differences in count computing: extra devices are required, out-of-device processing, etc. This paper presents a study to discover whether the estimation of energy expenditure is dependent on the accelerometer of the device used in measurements and to discover the suitability of each device for performing certain physical activities. In order to achieve this objective, we have conducted several experiments with different subjects on the basis of the performance of various daily activities with different smartphones and IMUs.Keywords
This publication has 24 references indexed in Scilit:
- Using accelerometers to measure physical activity in large-scale epidemiological studies: issues and challengesBritish Journal of Sports Medicine, 2013
- Actigraph GT3X: Validation and Determination of Physical Activity Intensity Cut PointsInternational Journal of Sports Medicine, 2013
- Estimating Activity and Sedentary Behavior from an Accelerometer on the Hip or WristMedicine & Science in Sports & Exercise, 2013
- Frailty in elderly peopleThe Lancet, 2013
- Embedded fall and activity monitoring for a wearable ambient assisted living solution for older adults2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2012
- Evaluation of artificial neural network algorithms for predicting METs and activity type from accelerometer data: validation on an independent sampleJournal of Applied Physiology, 2011
- Energy expenditure: components and evaluation methods.2011
- A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity MonitoringSensors, 2010
- Physical activity and energy expenditure measurements using accelerometers in older adults.2010
- Detection of Type, Duration, and Intensity of Physical Activity Using an AccelerometerMedicine & Science in Sports & Exercise, 2009