Three-dimensional finite element analysis of translaminar lag screw designs for L5 bilateral spondylolysis
Authors:
Open Access
- 13 August 2026
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 14, 1882221
Abstract
Purpose: This finite element study aimed to quantitatively compare the biomechanical properties of translaminar lag screws with different diameters and structural designs for the surgical repair of L5 bilateral spondylolysis, to provide evidence for individualized screw selection. Methods: An intact model of L4-S1 segment (Model A) and a L5 bilateral spondylolysis model (Model B) were established using Mimics, Geomagic, and SolidWorks. Additional models were constructed incorporating translaminar lag screws of varying diameters: 4.5 mm (solid, Model C1; cannulated, Model C2), 4.0 mm (solid, Model D1; cannulated, Model D2), and 3.5 mm (solid, Model E1; cannulated, Model E2). Following model validation, a 400 N axial load and a 10 N m moment were applied to simulate five conditions. Analyzed parameters included range of motion (ROM), maximum displacement, and maximum von Mises stress in the disc, pars interarticularis, and fixation screws. Results: Compared to the intact model (A), the spondylolysis model (B) showed significant instability. All fixation models (C1-E2) effectively restored ROM to intact levels, regardless of screw diameter or structural design. Larger-diameter (4.5 mm) and solid designs demonstrated slightly better control of model displacement. Increasing diameter significantly reduced stress concentrations within the pars interarticularis and fixation screws. For a given diameter, cannulated screws sustained higher stress than solid screws. The 3.5 mm cannulated screw exhibited the highest screw stress, approaching the yield strength of titanium alloy under rotational loading. Conclusion: All translaminar lag screw designs can effectively restore stability in L5 spondylolysis. While different diameters and structural designs have a minor impact on stability restoration, they significantly affect implant stress. In this specific patient-derived model, the 4.5 mm solid screw demonstrated the most favorable biomechanical profile, with the lowest stress on the implant and effective control of graft displacement. These findings suggest a potential mechanical advantage for 4.5 mm solid screws; however, confirmation through multi-specimen studies or clinical trials is required before broader clinical recommendations can be made.Keywords
This publication has 33 references indexed in Scilit:
- Lumbar spondylolysis - Current concepts reviewJournal of Clinical Orthopaedics and Trauma, 2021
- Biomechanical Changes of Adjacent and Fixed Segments Through Cortical Bone Trajectory Screw Fixation versus Traditional Trajectory Screw Fixation in the Lumbar Spine: A Finite Element AnalysisWorld Neurosurgery, 2021
- Characterization of the L4–L5–S1 motion segment using the stepwise reduction methodJournal of Biomechanics, 2016
- Bilateral pedicle screw fixation provides superior biomechanical stability in transforaminal lumbar interbody fusion: a finite element studyThe Spine Journal, 2015
- Long-term results of the direct repair of spondylolisthesisEuropean Spine Journal, 2011
- Direct repair of spondylolysis by TSRH’s Hook plus screw fixation and bone grafting: biomechanical study and clinical reportArchives of orthopaedic and trauma surgery, 2009
- Finite element analysis of the spine: Towards a framework of verification, validation and sensitivity analysisMedical Engineering & Physics, 2008
- Buck’s direct repair of lumbar spondylolysis restores disc stresses at the involved and adjacent levelsClinical Biomechanics, 2006
- Biomechanical comparison between fusion of two vertebrae and implantation of an artificial intervertebral discJournal of Biomechanics, 2006
- Three dimensional surgical simulations of the spineJournal of Biomedical Engineering, 1982