The Influence of Specimen Attachment and Dimension on Microtensile Strength
Authors:
- 1 May 2004
- journal article
- other
- Published by SAGE Publications in Journal of Dental Research
- Vol. 83 (5) , 420-424
Abstract
The higher microtensile bond strength values found for specimens with a smaller cross-sectional area are often explained by the lower occurrence of internal defects and surface flaws. We hypothesized that this aberrant behavior is mainly caused by the lateral way of attachment of the specimens to the testing device, which makes the strength dependent on the thickness. This study showed that composite bars of 1×1×10, 1×2×10, and 1×3×10mm attached at their 1-mm-wide side (situation A) fractured at loads of the same magnitude, as a result of which the microtensile strength (μTS), calculated as F/A (force at fracture/cross-sectional area), significantly increased for specimens with decreasing thickness. Attachment at the 1-, 2-, or 3-mm-wide side (situation B) resulted in equal μTS values (P > 0.05). Finite element analysis showed different stress patterns for situation A, but comparable patterns for situation B. Both situations showed the same maximum stress at fracture.Keywords
This publication has 9 references indexed in Scilit:
- The influence of cross-sectional shape and surface area on the microtensile bond testDental Materials, 1998
- Why do Shear Bond Tests Pull Out Dentin?Journal of Dental Research, 1997
- Shear vs. Tensile Bond Strength of Resin Composite Bonded to CeramicJournal of Dental Research, 1995
- Three-dimensional finite element analysis of the shear bond testDental Materials, 1995
- Relationship between surface area for adhesion and tensile bond strength — Evaluation of a micro-tensile bond testDental Materials, 1994
- Bond strength of six dentinal adhesivesJournal of Dentistry, 1994
- Analysis of the "Shear" Bond Strength of Pretreated Aged Composites Used in Some Indirect Bonding TechniquesJournal of Dental Research, 1993
- In vitro quality testing of dentin adhesivesActa Odontologica Scandinavica, 1993
- A critique of bond strength measurementsJournal of Dentistry, 1989