Abstract
To evaluate the suitability of Colilert-18 in detecting Escherichia coli and total coliforms in tropical freshwater samples. Target organisms were isolated from yellow-fluorescent and yellow wells of Colilert-18/Quanti-Tray using m-TEC agar and m-ENDO LES agar respectively. All the selected isolates were first identified based on their fatty acid methyl ester profile. Isolates showing contradictory results to that of the Colilert-18 procedure were re-identified using API 20E strips. A total of 357 isolates, 177 from yellow-fluorescent wells and 180 from yellow wells, were identified. The false-positive and -negative rates for E. coli detection using Colilert-18 were 36.4% and 11%, respectively, while for coliform detection the false-positive rate was 10.3%. The high false-positive rate of Colilert-18, tempers its value for E. coli detection when used for tropical freshwater samples.

This publication has 20 references indexed in Scilit: