Successful treatment of a patient with penetrating injury of the esophagus and brachiocephalic artery due to migration of Kirschner wires.

Authors:
  • TNTsuyoshi Noguchi
    Tsuyoshi Noguchi
  • THTsuyoshi Hashimoto
    Tsuyoshi Hashimoto
  • YUYuzo Uchida
    Yuzo Uchida
  • KKKatsunobu Kawahara
    Katsunobu Kawahara

  • 1 October 2005
    • journal article
    • case report
Abstract
Pins and wires offer the simplest and most effective tools for managing bone fractures and dislocations. Migration of these devices within the chest is rare, but can cause serious problems. The spontaneous migration of Kirschner wires from the right clavicle to the mediastinum resulted in penetrating injury of the esophagus and pseudo-aneurysm of the brachiocephalic artery in an 84-year-old patient. Two Kirschner wires were removed via a vertical incision on the right shoulder without thoracotomy and the brachiocephalic artery was replaced with a Dacron graft.