Flexible Piezoresistive Sensor Patch Enabling Ultralow Power Cuffless Blood Pressure Measurement
Top Cited Papers
- 17 December 2015
- journal article
- research article
- Published by Wiley in Advanced Functional Materials
- Vol. 26 (8) , 1178-1187
Abstract
Noninvasive and real‐time cuffless blood pressure (BP) measurement realizes the idea of unobtrusive and continuous BP monitoring which is essential for diagnosis and prevention of cardiovascular diseases associated with hypertension. In this paper, a wearable sensor patch system that integrates flexible piezoresistive sensor (FPS) and epidermal electrocardiogram (ECG) sensors for cuffless BP measurement is presented. By developing parametric models on the FPS sensing mechanism and optimizing operational conditions, a highly stable epidermal pulse monitoring method is established and beat‐to‐beat BP measurement from the ECG and epidermal pulse signals is demonstrated. In particular, this study highlights the compromise between sensor sensitivity and signal stability. As compared with the current optical‐based cuffless BP measurement devices, the sensing patch requires much lower power consumption (3 nW) and is capable of detecting subtle physiological signal variations, e.g., pre and postexercises, thus providing a promising solution for low‐power, real‐time, and home‐based BP monitoring.Keywords
Funding Information
- Chow Yuk Ho Technology Centre for Innovative Medicine
This publication has 35 references indexed in Scilit:
- Flexible polymer transistors with high pressure sensitivity for application in electronic skin and health monitoringNature Communications, 2013
- Oscillometric measurement of systolic and diastolic blood pressures validated in a physiologic mathematical modelBioMedical Engineering OnLine, 2012
- An Investigation of Pulse Transit Time as a Non-Invasive Blood Pressure Measurement MethodJournal of Physics: Conference Series, 2011
- Materials and Mechanics for Stretchable ElectronicsScience, 2010
- Mesoscale modeling of electrical percolation in fiber-filled systemsThe Journal of Chemical Physics, 2005
- Broadband ac conductivity of conductor-polymer compositesPhysical Review B, 1998
- Meyer's hardness law and its relation to other measures of ball hardness testsCrystal Research and Technology, 1997
- Blood pressure, stroke, and coronary heart disease *1Part 1, prolonged differences in blood pressure: prospective observational studies corrected for the regression dilution biasThe Lancet, 1990
- Measurements of Young's Modulus of Elasticity of the Canine Aorta with UltrasoundUltrasonic Imaging, 1979
- The velocity of pulse wave in manProceedings of the Royal Society of London. Series B, Containing Papers of a Biological Character, 1922